ecobee Thermostat Compressor Min Outdoor Temperature

What this problem usually means

Compressor Min Outdoor Temperature is an ecobee installer threshold for heat pump systems: the outdoor temperature below which the ecobee will not call for the heat pump compressor to run at all. Below this temperature the auxiliary heat source (electric strips or a gas furnace) does all the heating. It is set to 35F (1.7C) by default. It is a setting, not a fault: if your heat pump stops running on cold nights and the aux heat takes over, this threshold is usually why.

Likely causes

  1. The threshold is working as designed: the outdoor temperature is below the set point (35F by default), so the ecobee is holding the compressor off
  2. The threshold was set higher than the heat pump needs, so the compressor is locked out in weather it could still heat in
  3. The threshold was set lower than the heat pump can safely handle, which ecobee warns can damage the compressor

How to fix it — step by step

  1. Confirm the pattern first: the heat pump should run normally in milder weather and stop only when the outdoor temperature drops below the threshold. If the heat pump never runs at any temperature, this setting is not the whole story: check the breaker and the outdoor unit before changing settings.
  2. Open the setting on the thermostat itself (it cannot be changed in the app): Main Menu, then Settings, then Installation Settings, then Thresholds, then Compressor Min Outdoor Temperature. Note the current value before touching it.
  3. Compare the value with your heat pump's own documentation: ecobee's guidance is to ask the heat pump manufacturer for the safest minimum, which is also printed in the heat pump's manual or on its specification sticker. Never set the threshold below the manufacturer's minimum: running a compressor colder than it is rated for can damage it.
  4. If the value is higher than the manufacturer's minimum and the aux heat bills are the complaint, lower the threshold toward the manufacturer's figure, in small steps. If it is already at or below the manufacturer's minimum, leave it alone: the setting is protecting the compressor.
  5. Check the partner setting while you are in Thresholds: Aux Heat Max Outdoor Temperature (50F by default) is the warmest outdoor temperature at which aux heat is allowed to run. If aux heat runs in mild weather, that value, or the Aux Savings Optimization staging value, is the one to look at.
  6. After any change, watch the next cold night: the compressor should keep running down to the new threshold and the aux heat should engage only below it or when the heat pump cannot hold the setpoint.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

This fault usually does not need a replacement part - the fix is in the steps above. If your thermostat does need a part, start with the link above.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.