What this problem usually means
ecobee's Aux Heat Runtime Alert is a configurable alert, not a numeric fault code: ecobee's Reminders & Alerts article says it 'Alerts you if the Auxiliary heat source runs for more than the set amount in a 24-hour period. This is set to 3 hours by default.' On a heat-pump system, auxiliary (backup) heat is the expensive heat — long aux runs usually mean the heat pump is not carrying the load, the weather is below the heat pump's effective range, or the thresholds are letting aux take over too readily.
Likely causes
- Auxiliary heat ran longer than the set runtime (default 3 hours) in 24 hours — ecobee's published trigger for this alert
- Heat pump unable to keep up (very cold weather, or a heat-pump fault), so aux heat fills the gap
- Aux-heat threshold settings in Installation Settings letting auxiliary heat take over too readily, even in weather the heat pump could handle
How to fix it — step by step
- Note the pattern before changing anything: a single alert during an extreme cold snap can be normal operation; repeated alerts in mild weather are the signal that the heat pump is underperforming
- Check the heat pump is actually running during a heat call (outdoor unit on, fan turning) using the ecobee equipment test for Heat Pump Heat Stage 1 — a heat pump that does not run forces aux to do everything
- Review the aux-heat thresholds in Installation Settings (ecobee links its guide on minimizing auxiliary heat use from this article) rather than just raising the alert limit to silence it
- If the heat pump does not run in test mode, or aux runtime stays excessive in mild weather, the pinpoint is the heat-pump system — book an HVAC technician and report the aux runtime alert pattern
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix it
No specific replacement part is documented for this fault. If the checks above do not clear it, your thermostat likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.