ecobee Thermostat ecobee thermostat (alert numbers published in the ecobee API Alert object documentation) 1006 Error Code
What the 1006 code means
Problem with cooling. The thermostat called for cooling and the system did not cool as expected.
Likely causes
- The cooling equipment failed to start or stopped during the call.
- A safety switch, such as a condensate float switch, opened during the call.
How to fix it — step by step
- Set the thermostat to Cool below room temperature. If nothing starts, check the air handler and outdoor unit breakers and the furnace access door. Any one of those open blocks the whole cooling call.
- If the indoor blower runs but the outdoor unit does not, check the condensate drain pan at the indoor unit for standing water. A full pan trips the float switch and stops the outdoor unit while the blower keeps running.
- Clear the drain and retest. Cooling restored means the blocked drain was the cause.
- If drains are clear and power is on and the system still does not cool, the fault is in the cooling equipment. Call a pro.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the 1006 code
No specific replacement part is documented for this fault. If the checks above do not clear it, your thermostat likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.