What the 1007 code means
Communication to EI failed. The thermostat cannot communicate with the Equipment Interface module.
Likely causes
- The wiring between the thermostat and the Equipment Interface module is loose or damaged.
- The Equipment Interface module has lost power.
How to fix it — step by step
- Locate the Equipment Interface module. On ecobee systems that use one, it is mounted at or near the furnace or air handler.
- Check that the module has power. If its indicator is dark while the furnace has power, the module or its power wiring is the fault.
- Turn off power at the furnace switch, then check each wire between the thermostat and the module for a loose terminal or a nicked conductor. Reseat any loose wire and restore power.
- If communication returns, the loose connection was the cause. If the module has power and the wiring is sound and the alert stays, the module itself has failed and should be replaced by a pro.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Equipment Interface module.
Parts that commonly fix the 1007 code
- Equipment Interface moduleShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.