CodeWhat it meansCheck first
1000Cold temp alert. The indoor temperature has fallen to the low temperature alert level set on the thermostat.The heating system is off, has failed, or cannot keep up with outdoor conditions.›
1001Hot temp alert. The indoor temperature has risen to the high temperature alert level set on the thermostat.The cooling system is off, has failed, or cannot keep up with outdoor conditions.›
1002Sensor activated shutting down compressor. A configured sensor input has tripped and the thermostat has shut…A sensor wired to a thermostat input, such as a condensate or safety sensor, has›
1003Problem with furnace/boiler heating. The thermostat called for heat and the furnace or boiler did not heat as…The furnace or boiler failed to ignite or stopped during the call.›
1004Problem with heatpump heating. The thermostat called for heat pump heat and the heat pump did not heat as…The heat pump failed to start or stopped during the call.›
1006Problem with cooling. The thermostat called for cooling and the system did not cool as expected.The cooling equipment failed to start or stopped during the call.›
1007Communication to EI failed. The thermostat cannot communicate with the Equipment Interface module.The wiring between the thermostat and the Equipment Interface module is loose or›
1009Problem with aux heat, running too much. Auxiliary heat has run longer than the aux heat runtime alert…The heat pump cannot carry the load alone, so auxiliary heat is filling in for long›
1010Aux heat used with high outdoor temp. Auxiliary heat ran while the outdoor temperature was above the aux…The thermostat or heat pump control called aux heat when it was not needed.›
1020Low humidity alert. Indoor humidity has fallen to the low humidity alert level set on the thermostat.The home is genuinely dry, which is common in heating season.›
1021High humidity alert. Indoor humidity has risen to the high humidity alert level set on the thermostat.The cooling system is not removing enough moisture, often from short cooling runs.›
1026Low battery. A battery powered ecobee device reporting to the thermostat, such as a remote sensor, has a low…The battery in a remote sensor or other battery powered ecobee device is nearly›
1027Remote sensor detected. A remote sensor has been detected by the thermostat. This is a status alert, not a…A new or re-powered remote sensor has paired or checked in with the thermostat.›
1028Remote sensor not communicating. A remote sensor has stopped reporting to the thermostat.The sensor battery is dead.›
1030Invalid current temp reading. The thermostat is not getting a valid temperature reading.The thermostat internal temperature sensor has failed or its reading is out of range.›
1032Faulty humidity sensor. The thermostat humidity sensor is reporting a faulty reading. ecobee lists alert…The thermostat internal humidity sensor has failed.›
3130Furnace maintenance reminder. The furnace filter or furnace service reminder interval set on the thermostat…The run time or calendar interval set for the furnace filter reminder has elapsed.›
3131Humidifier maintenance reminder. The humidifier maintenance interval set on the thermostat has expired.The interval set for humidifier pad or humidifier service has elapsed.›
3132Ventilator maintenance reminder. The ventilator maintenance interval set on the thermostat has expired.The interval set for ventilator filter or core service has elapsed.›
3133Dehumidifier maintenance reminder. The dehumidifier maintenance interval set on the thermostat has expired.The interval set for dehumidifier filter service has elapsed.›
3135UV maintenance reminder. The UV lamp maintenance interval set on the thermostat has expired.The interval set for UV lamp replacement has elapsed. UV lamps lose output with age›
3136AC maintenance reminder. The air conditioner maintenance interval set on the thermostat has expired.The interval set for AC service has elapsed.›
3140Hvac maintenance reminder. The general HVAC service reminder interval set on the thermostat has expired.The interval set for general HVAC maintenance has elapsed.›