Carrier Furnace 42 Error Code
What the 42 code means
Inducer motor fault on Carrier variable-speed two-stage furnaces such as the 58MVP/58UVB. The inducer did not start within about 20 seconds of a call for heat, its RPM is outside the valid range, or its RPM signal was lost during operation.
Likely causes
- Failed inducer motor
- Restricted combustion air supply or vent
- Improper vent sizing
- Loose or damaged inducer motor wiring
How to fix it — step by step
- Check the outdoor intake and exhaust pipes for snow, ice or debris and clear what you can reach
- Note the code for the technician
- Cycle power once at the service switch
- If 42 returns, call a technician - a furnace that cannot run its inducer cannot vent combustion gases safely
Parts that commonly fix the 42 code
- inducer motor - Shop at RepairClinic
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.