Carrier Furnace 13 Error Code

What the 13 code means

Limit circuit lockout. On Carrier 58-series furnaces, code 13 occurs when a limit, draft safeguard, flame rollout or blocked vent switch stays open longer than 3 minutes (on some two-stage models, also after repeated limit trips in high heat). The control locks out and auto-resets after 3 hours; see code 33 for the underlying fault.

Likely causes

  1. Repeated overheating from restricted airflow (dirty filter, blocked ducts)
  2. Flame rollout switch tripped
  3. Defective limit switch or loose connections
  4. Restricted or improperly sized vent

How to fix it — step by step

  1. Turn the thermostat down and let the furnace cool completely
  2. Check the air filter and replace it if it is dirty
  3. Open all supply registers and make sure return grilles are not blocked
  4. Wait for the 3-hour auto-reset or cycle power once at the service switch
  5. If 13 returns, stop resetting and call a technician - a tripped flame rollout switch must be diagnosed, never just reset

Parts that commonly fix the 13 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.