Briggs & Stratton Generator Home Generator System (air-cooled, FC display) Starts Then Stops

What this problem usually means

The engine shuts down during operation. On this family a shutdown in service is almost always either the fuel supply or a protective fault that the blinking indicator is already reporting.

Likely causes

  1. Fuel supply turned off or depleted during the run
  2. A fault condition detected, with the fault indicator blinking

How to fix it — step by step

  1. Check the fuel side first: fuel valves open and the propane tank not empty. A tank that ran dry mid-outage is the plain cause, and refilling or opening the supply is the fix.
  2. If fuel is proven, count the blinks on the fault indicator and match them to the fault code list, FC_1 through FC_8. The blink count is the diagnosis: two blinks is low oil pressure, seven is high temperature, and each code has its own correction.
  3. Work the correction for the code you counted, reset the system switch OFF for 30 seconds or more, return to AUTO and run the set. A full run with no shutdown and no blinking is the completed fix.
  4. If the set shuts down again with no blink pattern and fuel proven, the pinpoint is an unreported engine or control fault. Contact a local service facility and report how long it runs before stopping.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Briggs & Stratton Generator Home Generator System (air-cooled, FC display) problems

See all Briggs & Stratton Home Generator System (air-cooled, FC display) codes & guides →