Briggs & Stratton Generator Home Generator System (air-cooled, FC display) FC_7 - High Temperature
What it should look like on your machine
then it repeats
7 blinks - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Fault code FC_7, seven blinks on the LED indicator. The temperature switch contacts are normally open. If engine temperature exceeds approximately 149 degrees C (300 degrees F), the fault is detected and the engine shuts down.
Likely causes
- Running the unit with access doors removed
- Obstructed air inlet or exhaust port
- Low oil level
- Debris in the engine cylinder cooling fins
How to fix it — step by step
- Let the engine cool down fully before opening anything. Hot engine and exhaust parts cause severe burns.
- Remove any accumulated debris and obstructions from the air inlet, exhaust port and cooling fins. Check the oil level and correct it if low, since low oil is a named cause on this family.
- Ensure all access doors are installed whenever the unit is running. Doors off changes the cooling airflow and will trip this fault on its own.
- Reset the fault detection system and run the set under observation. Temperature holding with no FC_7 is the fix. A repeat shutdown with airflow, doors and oil all proven pinpoints the cooling or temperature switch side, which is dealer service.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Engine oil.
Parts that commonly fix it
- Engine oilShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Briggs & Stratton Generator Home Generator System (air-cooled, FC display) problems
- FC_8 - Transfer Switch Fault
- Starts Then Stops
- Won't Start
- Won't Turn On
- Does Not Transfer
- FC_1 - Low Battery Voltage
- FC_2 - Low Oil Pressure
- FC_3 - Low Voltage
- FC_4 - Engine Fail to Start
- FC_5 - Low Frequency
- FC_6 - Engine Overspeed
See all Briggs & Stratton Home Generator System (air-cooled, FC display) codes & guides →