Briggs & Stratton Generator Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 16 problems covered.

Not sure of the code? Tap along with it

If your Briggs & Stratton Generator blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Finding your model number: it is on the unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

Home Generator System (air-cooled, FC display)

ProblemWhat it meansCheck first
Does Not TransferThe generator runs but there is a loss of power on the essential circuits, so the house loads never pick up…Generator circuit breaker open›
FC_1 - Low Battery VoltageFault code FC_1, one blink on the indoor fault LED indicator. The generator cannot start because the starting…Faulty battery›
FC_2 - Low Oil PressureFault code FC_2, two blinks on the indoor fault LED indicator. The oil pressure switch uses normally closed…Oil level low, letting pressure fall below the 8 psi range›
FC_3 - Low VoltageFault code FC_3, three blinks on the LED indicator. Generator output voltage is low enough for the controller…Restriction in the fuel flow›
FC_4 - Engine Fail to StartFault code FC_4, four blinks on the LED indicator. Each start attempt cranks for 10 seconds, pauses for 10…No fuel supply, valves closed or tank empty›
FC_5 - Low FrequencyFault code FC_5, five blinks on the LED indicator. The feature protects devices connected to the transfer…Excessive loads on the generator›
FC_6 - Engine OverspeedFault code FC_6, six blinks on the LED indicator. The generator shuts down at the preset speed limit: if…Failed engine component in the governing path›
FC_7 - High TemperatureFault code FC_7, seven blinks on the LED indicator. The temperature switch contacts are normally open. If…Running the unit with access doors removed›
FC_8 - Transfer Switch FaultFault code FC_8, eight blinks on the LED indicator, on units where the transfer switch is equipped with fault…Blown fuse in the transfer switch›
Starts Then StopsThe engine shuts down during operation. On this family a shutdown in service is almost always either the fuel…Fuel supply turned off or depleted during the run›
Won't StartThe engine will not start, or starts and runs rough. Carbon monoxide warning: never run or crank this…15 Amp fuse missing or blown›
Won't Turn OnThe set is completely dead, or a fault is present but the indoor fault LED is not blinking at all. That…Battery completely discharged, so the LED cannot blink a fault›

Standby Generator System (liquid-cooled, scrolling-text controller, 076191 family)

ProblemWhat it meansCheck first
Engine Does Not StartThis service code is indicated by ENGINE DOES NOT START in the display. Each time the system is directed to…No fuel supply, or an incorrect fuel selector setting›
High Coolant TemperatureThis service code is indicated by HIGH COOLANT TEMPERATURE in the display. If the engine temperature exceeds…Running the unit with an access panel removed›
Low Oil PressureThis service code is indicated by LOW OIL PRESSURE in the display. If oil pressure drops below approximately…Oil level low›
Transfer Switch FaultThis service code is indicated by TRANSFER SWITCH FAULT in the display, on units where the transfer switch is…Blown fuse in the transfer switch›
Looking for a part?

Once you know the part you need, browse Briggs & Stratton Generator replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.