What the E010 code means
Data memory error in the user interface on 300, 500 and 800 Series built-in wall ovens: a memory check or write failed and all heating elements are disabled until the error clears at start-up.
Likely causes
- failed data memory in the user interface
- user interface electronics fault
- power interruption during a memory write
How to fix it — step by step
- Turn the oven off at the breaker for 30 seconds and restore power to restart it
- If the code returns at start-up, stop using the oven
- Book a technician - Bosch's service information points to replacing the user interface
Parts that commonly fix the E010 code
- user interface - Shop at RepairClinic