York Furnace Modulating furnace control — TPLCC 5 amber flashes
What this problem usually means
Heating capacity is reduced due to a restriction in the combustion air or vent system on York TPLCC modulating furnaces. The manual advises checking for a blocked vent/air pipe or clogged condensate drain; above 4,000 feet it can also indicate normal altitude derating.
Likely causes
- blocked vent or combustion air pipe
- clogged condensate drain
- high-altitude derating
How to fix it — step by step
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- Check the condensate drain line and trap are not clogged
- Replace the air filter if it is dirty → Shop the air filter at RepairClinic
- If capacity stays reduced, call a technician
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the air filter.
Parts that commonly fix it
- air filter - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.