York Furnace Modulating furnace control — TPLCC 5 amber flashes

What this problem usually means

Heating capacity is reduced due to a restriction in the combustion air or vent system on York TPLCC modulating furnaces. The manual advises checking for a blocked vent/air pipe or clogged condensate drain; above 4,000 feet it can also indicate normal altitude derating.

Likely causes

  1. blocked vent or combustion air pipe
  2. clogged condensate drain
  3. high-altitude derating

How to fix it — step by step

  1. Check the outdoor vent and intake pipes are clear of snow, ice or debris
  2. Check the condensate drain line and trap are not clogged
  3. Replace the air filter if it is dirty → Shop the air filter at RepairClinic
  4. If capacity stays reduced, call a technician