Whirlpool Water heater Energy Smart electric 4 flashes
What it should look like on your machine
then it repeats
4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Upper element circuit failure. The control called for the upper element and the circuit did not respond correctly.
Likely causes
- Upper heating element failed (outside 5–25 ohms)
- Damaged wires at the element or the control board
- Failed control board
How to fix it — step by step
- Remove power from the heater at the breaker and verify off. Locate the suspect part: the upper heating element is screwed into the upper part of the tank behind the upper access panel on the side of the tank. Access: remove the upper access panel screws, fold back the insulation and remove the plastic element/thermostat cover — the element terminals are right there; the control board connections are at the same control area.
- Check the upper element circuit for resistance of 5–25 ohms at its terminals (wires lifted): outside that range means the upper element has failed — that is the pinpoint. In range means the element is good and you move to wiring/control.
- Check the wires at the element and at the board for damage and repair or replace them — a burnt or loose wire opens the circuit like a failed element.
- Replace a failed upper element: shut off the cold supply, drain the tank below the upper element through the drain valve at the base, remove the power wires, unscrew the element with an element wrench, clean the tank threads, fit the new element with its rubber gasket, tighten, refill the tank completely with a hot faucet open until all air is purged (an upper element energised in air burns out immediately), check for leaks, refit wires, cover, insulation and panel, restore power.
- If the 4-flash condition continues with a good element and good wiring, replace the control board.
- Tell the technician: 4 flashes upper element circuit, the upper element's measured resistance, and the wire condition at element and board. What this job involves: 240 V electrical work and partial tank draining.
- Verify after the repair: restore power and water, then open a hot tap and let the heater bring the water back up - hot water should return at the tap with the problem gone. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the upper heating element.
Shop the upper heating element at Amazon
Also tied to this fault: control board - Shop at Amazon
Parts that commonly fix it
- upper heating element$10–$50Shop at Amazon
- control board$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Whirlpool manual is on Whirlpool's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.