Whirlpool Water heater Energy Smart electric 2 flashes
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Water temperature exceeded the high limit. The control shut the heater down on overheat.
Likely causes
- Access doors or insulation out of place, skewing temperature sensing
- Element circuit fault driving an overheat
- Failed heating element
How to fix it — step by step
- Make sure the upper and lower access doors and insulation are properly in place first — displaced insulation/doors skew the temperature sensing that feeds this high-limit trip, and refitting them may be the whole fix.
- Remove power at the breaker and verify off. The suspect parts are the two immersion elements: the upper element is behind the upper access panel on the side of the tank and the lower element behind the lower access panel; for each, remove the panel screws, fold back the insulation and remove the plastic element/thermostat cover to reach the element terminals.
- Check each element circuit for resistance of 5–25 ohms at its terminals (wires lifted): an element outside that range has failed and is the overheat suspect; both elements in range sends you to the control/sensing side — tell the technician both readings.
- Replace a failed element: shut off the cold supply, drain the tank below that element's level through the drain valve at the base, remove the power wires, unscrew the element with an element wrench, clean the tank threads, fit the new element with its rubber gasket (a drop of dish liquid lubricates the gasket), tighten, refill the tank fully with a hot faucet open until air is purged — never energise an element in an empty tank — check for leaks, then refit wires, cover, insulation and panel and restore power.
- Reset the control system and prove a full heating cycle without a repeat 2-flash trip.
- Tell the technician: 2 flashes high-limit, each element's measured resistance, and whether the access doors/insulation were displaced. What this job involves: 240 V electrical work and partial tank draining — the shock hazard is real until the breaker is off and verified.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the upper heating element.
Shop the upper heating element at Amazon
Also tied to this fault: lower heating element - Shop at Amazon
Parts that commonly fix it
- upper heating element$10–$50Shop at Amazon
- lower heating element$10–$50Shop at Amazon
- Tools for this job, if you need them$10–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Whirlpool manual is on Whirlpool's support site — you'll need your model number.