Sony TV EX2L chassis (KLV-40/46/52V530A, KLV-40/46/52V550A) 5 Blinks

What it should look like on your machine

then it repeats

5 blinks - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

The red standby LED blinks five times, pauses, and repeats. On EX2L-chassis models (KLV-V530A/V550A series) Sony's service manual Standby LED Error Display lists 5 blinks as DC_ALERT, with the countermeasure 'Replace BA board' — a DC voltage alert on the main (BA) board, NOT the T-Con/panel meaning 5 blinks carries on AZ/GN1T chassis (on EX2L, T-Con is 14 blinks and Balancer is 13 blinks). Always confirm against your exact model's service documentation.

Likely causes

  1. DC voltage alert (DC_ALERT) detected by the main (BA) board
  2. Power supply board not outputting correct DC voltages
  3. Failed main (BA) board

How to fix it — step by step

  1. Perform a power reset: unplug the TV for 2 minutes, then plug back in and retest
  2. Disconnect all external devices including HDMI cables and retest
  3. Per the EX2L service manual's countermeasure for 5 blinks, the main (BA) board is the replacement suspect — have it checked and, if faulty, replaced with a board matched to your exact model number
  4. If voltages from the power supply board are wrong, have the power supply board serviced first

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.