Sharp TV Aquos LE650U series Regular Communication Error (3 Slow + 3 Fast Flashes)

What this problem usually means

On Sharp Aquos LE650U-family models (LC-60/70LE650U, C6500U, LE657U, LE755U, LE757U, LE857U, C7500U), the center icon LED flashing slowly three times then fast three times is a regular communication error: the regular communication performed at 1-second intervals during normal operation has been interrupted, which the service manual attributes to a main CPU operation failure or a monitor microcomputer reception failure. Unlike the start-up codes, this one typically appears after the set has been running.

Likely causes

  1. Failed main board (main CPU operation failure)
  2. Monitor microcomputer reception failure
  3. Overheating main board interrupting communication
  4. Intermittent board connector

How to fix it — step by step

  1. Unplug the TV for at least 60 seconds, let it cool if it has been running in a warm or enclosed space, then plug back in and retry
  2. Access (Sharp LE650U service manual, Chapter 4 'Removing of Major Parts', read for this batch): unplug the TV, remove the 4 stand lock screws and detach the stand, remove the AC cord cover screw, disconnect the AC wire, then remove the rear cabinet's lock screws (10 + 2 + 18 on the 60-inch) and lift the rear cabinet off, taking care not to trap the backlight LED and speaker harnesses when refitting. Inside, the units are separate boards: the POWER/LED DRIVER unit (the power supply, where the AC cord connects), the MAIN unit (the main board, carrying the input sockets), and the LCD CONTROL unit (the T-Con). Each unit is removed by disconnecting all its connectors and removing its lock screws (4 screws each for the power and main units on the family procedure).
  3. Have a technician check the main unit — including whether it is overheating in its installed position, since this code interrupts a running set: communication failing again after a cool, ventilated restart with rails correct = main CPU operation failure on the main unit.
  4. Replace the main board with one matched to your exact model number if the CPU communication keeps failing. → Shop the main board at Amazon
  5. Replacement pattern for the condemned unit: photograph and note every connector, disconnect them, remove the unit's lock screws, fit the replacement matched to your exact model number (and, for the main unit, its unit code — different MAIN unit codes by model), reconnect everything, refit the rear cabinet without trapping harnesses, and confirm the flash pattern is gone.
  6. Tell the technician: the exact model number, the blink/LED pattern you counted, what you already tried (power reset, direct wall outlet, devices disconnected), and which board the tests above condemned — that saves a repeat diagnosis visit.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $80–$300Typical pro repair $200–$500
  • main board$80–$300Shop at Amazon
  • Tools for this job, if you need them$10–$40

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Sharp manual is on Sharp's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Sharp TV Aquos LE650U series problems