Sharp TV Aquos LE650U series Other Communication Error (3 Slow + 5 Fast Flashes)
What this problem usually means
On Sharp Aquos LE650U-family models (LC-60/70LE650U, C6500U, LE657U, LE755U, LE757U, LE857U, C7500U), the center icon LED flashing slowly three times then fast five times is 'other communication error': when the main microcomputer sends a request, the command is not output from the main CPU - a main CPU operation failure or monitor microcomputer reception failure.
Likely causes
- Failed main board (main CPU operation failure)
- Monitor microcomputer reception failure
- Corrupted firmware
- Main board power rail fault
How to fix it — step by step
- Unplug the TV for at least 60 seconds, then plug back in and retry once
- Access (Sharp LE650U service manual, Chapter 4 'Removing of Major Parts', read for this batch): unplug the TV, remove the 4 stand lock screws and detach the stand, remove the AC cord cover screw, disconnect the AC wire, then remove the rear cabinet's lock screws (10 + 2 + 18 on the 60-inch) and lift the rear cabinet off, taking care not to trap the backlight LED and speaker harnesses when refitting. Inside, the units are separate boards: the POWER/LED DRIVER unit (the power supply, where the AC cord connects), the MAIN unit (the main board, carrying the input sockets), and the LCD CONTROL unit (the T-Con). Each unit is removed by disconnecting all its connectors and removing its lock screws (4 screws each for the power and main units on the family procedure).
- Have a technician verify the main unit's supply rails and check the stored error cause (MONITOR ERR CAUSE in the adjustment process mode): rails correct with the command still not output from the main CPU = main unit failure.
- Replace the main board with one matched to your exact model number if the CPU has failed. → Shop the main board at Amazon
- Replacement pattern for the condemned unit: photograph and note every connector, disconnect them, remove the unit's lock screws, fit the replacement matched to your exact model number (and, for the main unit, its unit code, which differs by model), reconnect everything, refit the rear cabinet without trapping harnesses, and confirm the flash pattern is gone.
- Tell the technician: the exact model number, the blink/LED pattern you counted, what you already tried (power reset, direct wall outlet, devices disconnected), and which board the tests above condemned — that saves a repeat diagnosis visit.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the main board.
Parts that commonly fix it
- main board$80–$300Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Sharp manual is on Sharp's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Sharp TV Aquos LE650U series problems
- Panel Power Supply Error (2 Slow + 5 Fast Flashes)
- Regular Communication Error (3 Slow + 3 Fast Flashes)
- Start-Up Confirmation Communication Error (3 Slow + 2 Fast Flashes)
- Temperature Error (4 Slow + 1 Fast Flash)
- AC_DET Error (2 Slow + 1 Fast Flash)
- Digital 3.3V Error (2 Slow + 3 Fast Flashes)
- Initial Communication Error (3 Slow + 1 Fast Flash)
- Lamp Error (1 Slow + 1 Fast Flash)
- Main 13V Error (2 Slow + 2 Fast Flashes)
- Main Microprocessor Error (4 Slow + 3 Fast Flashes)