Raypak Pool heater Ignition Lockout

What this problem usually means

On Raypak Digital gas pool heaters (206A-406A), Ignition Lockout means the automatically lighted pilot did not establish or hold flame in the allowed trial time - shown as No pilot sensed, or the pilot went out during the main burner trial (Main Ign Failure).

Likely causes

  1. gas shutoff closed or low gas supply
  2. dirty pilot orifice
  3. faulty igniter or spark lead
  4. failed pilot or gas valve

How to fix it — step by step

  1. Confirm the manual gas shutoff valve by the heater is open
  2. Check the vent is clear of debris from outside
  3. Reset the heater once only
  4. If it locks out again, turn it off and call a qualified gas pool heater technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Raypak pool heater problems

See all Raypak pool heater codes & guides →