Raypak Pool heater Ignition Failure
What this problem usually means
On Raypak digital gas pool heaters (206A–406A family, and the same wording on 106A/156A models) fitted with the propane tab NOT broken, Ignition Failure is the demand-for-heat message the control shows when the pilot flame is not established: the display alternates 'Ignition Failure' with 'No pilot sensed' — the pilot flame was not established within 90 seconds. It is a different message from Ignition Lockout, which is the same failure on the propane-tab-broken configuration (a 15 or 90 second window depending on model), and from Ign 6 min Delay, which is the pilot being lost repeatedly during the main-burner trial. Raypak's own control-logic flowchart for this message is short: verify gas is reaching the heater, and verify the gas valve is operating (gas present at the tube fitting).
Likely causes
- No gas reaching the heater — manual gas shutoff by the heater closed, an empty or low propane tank, or air in a gas line that has been off or serviced
- Gas valve not operating — the valve is not opening or passing gas to the pilot tube (Raypak's flowchart check is gas present at the tube fitting)
- Dirty or partially blocked pilot orifice, so no usable pilot flame establishes for the flame sensor to prove
- Failed pilot gas valve output or ignition circuit on the control board, so the pilot is never supplied or never sparked
How to fix it — step by step
- Confirm the manual gas shutoff valve on the gas line by the heater is fully open, and on propane check the tank gauge — a near-empty tank starves the pilot first. If you smell gas at any point, stop: close the shutoff, do not touch electrical switches, and call your gas utility or a technician.
- Confirm the heater actually has a call for heat and proven water flow (pump running, filter clean) — this message only appears while there is a demand for heat, and no flow means no ignition attempt to judge.
- Reset the heater once only — one power cycle or one new call for heat — and watch the sequence from outside the cabinet: you should hear the spark and the pilot attempt. A pilot that never lights at all, with gas confirmed at the heater, points at the valve/pilot side, not the settings.
- Stop at the cabinet door: verifying gas at the tube fitting, testing the gas valve and servicing the pilot assembly are licensed gas work. A technician works Raypak's flowchart in order — gas supply to the heater first, then valve operation, then the pilot assembly and ignition circuit — and the part that fails that sequence is the fix.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the igniter.
Also tied to this fault: pilot assembly - Shop at Amazon
Parts that commonly fix it
- igniter$25–$90Shop at Amazon
- pilot assemblyShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Raypak manual is on Raypak's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.