Raypak Pool heater Hi Limit 1 is open

What this problem usually means

On Raypak Digital gas pool heaters (206A-406A), Hi Limit 1 is open means the first high-limit safety circuit has opened, usually because water through the heater got too hot or flow was too low. On ASME models this is a manual-reset fault cleared with the MODE button.

Likely causes

  1. low water flow through the heater
  2. dirty filter
  3. internal bypass or unitherm governor problem
  4. faulty high limit switch

How to fix it — step by step

  1. Turn the heater off and let it cool
  2. Confirm the pump runs through the whole heat cycle and clean the filter
  3. Check valves are fully open
  4. On ASME models only, press MODE once to reset after cooling
  5. If it trips again, stop and call a pool technician

Parts that commonly fix it

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Related Raypak pool heater problems

See all Raypak pool heater codes & guides →