Neato Robot vacuum Botvac 80 Error 4000

What this problem usually means

Error 4000: the LIDAR reports objects about 0.5m away in the middle of an open room - false readings from a misaligned laser sensor. One owner fixed it by recalibrating the sensor tube position while watching live ranges. (The reporting owner called his unit a 'Botvac D80', which is not an official model name; the thread is filed under Botvac 80.)

Likely causes

  1. Laser sensor tube knocked out of alignment inside the LIDAR turret
  2. A weak battery upsetting the sensor readings (rule out first)

How to fix it — step by step

  1. Check the battery under load first - a stored pack should read above 14V
  2. Remove the LIDAR cover, open the 4-screw cap on the sensor, and slightly rotate the sensor tube while watching live ranges in the NeatoControl program until readings are sane
  3. Reassemble and test in an open room

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: documented owner repair reports. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the underside label or in the app. It's the key to the right manual pages and the right parts.

Related Neato Robot vacuum Botvac 80 problems

See all Neato Botvac 80 codes & guides →