Laars Boiler Mascot FT series 20 Error Code

What the 20 code means

Mascot FT error 20 is a hard lock on the condensate switch circuit: the condensate switch reads open when closed is normal (condensate drain trap fault). The manual's checks are the condensate and main controller connections, the condensate sensor resistance (if zero, replace the switch), the condensate hose condition, the condensate line and termination for blockages, and the vent pipe for blockages.

Likely causes

  1. Condensate switch open (drain trap fault)
  2. Loose condensate or main controller connection
  3. Failed condensate switch (resistance zero)
  4. Damaged or disconnected condensate hose
  5. Blocked condensate line or termination
  6. Blocked vent pipe

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (20) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the condensate trap and switch are at the condensate outlet at the bottom of the boiler; the condensate hose and drain line run from the trap to the drain termination.
  4. Test: reseat the condensate connections at the switch and the main controller, measure the switch resistance (zero means replace the switch), and inspect the hose, line, and termination for blockage. A backed-up trap with a clear line points to the vent pipe check in the manual's list. → Shop the condensate switch at Amazon
  5. End at the pinpoint: clear the condensate blockage, replace the hose, or replace the Condensate switch as condemned; if the problem persists, replace the main control per the manual. Technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 20 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Laars Boiler Mascot FT series error codes

See all Laars Mascot FT series codes & guides →