Laars Boiler Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 7 codes covered.
Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
Mascot FT (Er codes)
The Mascot FT shows faults as Er plus a number (Er:11). The manual's error table gives each code's description, numbered remedies and its recovery type - Hard Lock (manual reset) or Soft Lock (clears when the condition clears).
| Code | What it means | Check first | |
|---|---|---|---|
| 10 | Mascot FT error 10 is a hard lock: the flame has extinguished 8 times. The manual's recovery is to press the… | Flame extinguished 8 times | › |
| 11 | Mascot FT error 11 is a hard lock: ignition has failed 10 times. The display shows it as Er:11. The manual's… | Ignition failed 10 times | › |
| 16 | Mascot FT error 16 is a hard lock: the operating temperature sensor detects water temperature greater than… | Operating temperature sensor reading above 203 F (95 C) | › |
| 20 | Mascot FT error 20 is a hard lock on the condensate switch circuit: the condensate switch reads open when… | Condensate switch open (drain trap fault) | › |
| 28 | Mascot FT error 28 is a soft lock: the overheat sensor is open or shorted. The manual says this error code… | Overheat sensor open or short | › |
| 32 | Mascot FT error 32 is a soft lock: the DHW sensor is open or shorted. The manual says this error code will go… | DHW sensor open or short | › |
| 33 | Mascot FT error 33 is a soft lock: the CH temperature sensor is open or shorted. The manual says this error… | CH temperature sensor open or short | › |
Common questions
What does Er 11 mean on a Laars Mascot FT?
Ignition failed 10 times and the boiler has hard locked - it will not retry on its own. The manual's remedies work through the gas supply, ignition and flame sensing before the control is suspected.
Once you know the part you need, browse Laars Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.