Keurig Coffee machine K-Supreme Plus Grounds in your coffee

What this problem usually means

Per the guide, grounds may have gathered in the exit or entrance needles. For hot water brews, or when transitioning from a coffee pod to a non-coffee pod (tea or cocoa), Keurig also advises cleaning both needles and performing 2 cleansing brews to limit grounds in the cup. A separate note covers excessive grounds in the pod assembly housing: do not use already-punctured pods, which can let grounds escape through holes in the lid.

Likely causes

  1. Grounds gathered in the exit needle of the K-Cup pod holder
  2. Grounds gathered in the brewer entrance needles
  3. An already-punctured pod reused, letting grounds escape through holes in its lid

How to fix it — step by step

  1. Turn the brewer off and unplug it before cleaning — Keurig warns there are sharp needles above and in the bottom of the K-Cup pod holder, so keep fingers out of the pod holder.
  2. Clean the exit needle: lift the handle, grasp the top of the K-Cup pod holder and push up from underneath until it releases, detach the funnel, and locate the exit needle on the inside bottom of the holder. Insert a straightened paper clip into the exit needle to loosen any coffee grounds — grounds moving free means the exit path was clogged.
  3. Clean the entrance needle(s): lift the handle and locate the entrance needle on the underside of the lid. Hold the handle up and carefully insert a straightened paper clip into all the holes, moving it gently to loosen grounds.
  4. Reassemble the pod holder (align it with the opening using the two front ribs as a guide and snap it into place from the top), lower the handle completely and run two water-only cleansing brews with no pod. Clean water with no grounds in the cup means the needle cleaning worked.
  5. Check the pod you used: if its lid was already punctured before brewing, discard it and brew with a fresh, unpunctured pod — grounds-free output with a fresh pod pinpoints the reused pod, not the needles.
  6. If grounds persist after needle cleaning, 2 cleansing brews and a fresh pod, the guide offers no further user step for this symptom.
  7. Verify the fix: refill the water tank and run a full brew cycle - the drink should finish normally and the indication stay clear. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.