Keurig Coffee machine K-Supreme Plus Brewing a partial cup

What this problem usually means

The guide lists three causes for a partial cup on the K-Supreme Plus: a clogged exit needle, a K-Cup Pod Holder that needs cleaning, and scale buildup requiring descaling. If the descale procedure has been repeated two times and it still brews a partial cup, contact Customer Service.

Likely causes

  1. Exit needle clogged with coffee grounds
  2. K-Cup pod holder dirty / grounds built up in the holder
  3. Scale buildup — brewer needs descaling

How to fix it — step by step

  1. Turn the brewer off and unplug it before cleaning — Keurig warns there are sharp needles above and in the bottom of the K-Cup pod holder, so keep fingers out of the pod holder.
  2. Clean the exit needle: lift the handle, grasp the top of the K-Cup pod holder and push up from underneath until it releases, detach the funnel, and locate the exit needle on the inside bottom of the holder. Insert a straightened paper clip into the exit needle to loosen any coffee grounds — grounds moving free means the exit path was clogged.
  3. Clean the entrance needle(s): lift the handle and locate the entrance needle on the underside of the lid. Hold the handle up and carefully insert a straightened paper clip into all the holes, moving it gently to loosen grounds.
  4. Reassemble the pod holder (align it with the opening using the two front ribs as a guide and snap it into place from the top), lower the handle completely and run two water-only cleansing brews with no pod. Clean water with no grounds in the cup means the needle cleaning worked.
  5. Brew a test cup at a full size and measure it: a full measure after needle cleaning pinpoints the clogged exit needle as the cause.
  6. If cups are still short, clean the K-Cup pod holder itself per the care instructions (holder out, funnel off, wash, snap back in) and retest.
  7. If still short, run the full descaling procedure. If you have repeated the descale procedure two times and it is still only brewing a partial cup, the guide ends the walk-through: contact Customer Service.
  8. Verify after the repair: refill the water tank and run a full brew cycle - the drink should finish normally and the indication stay clear. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating label on the back or underside of the machine. It's the key to the right manual pages and the right parts.