Honeywell Thermostat T6 Pro Smart 177 Error Code
What the 177 code means
On a Honeywell T6 Pro Smart, alert 177 means 'Indoor Temperature Sensor Error': the wired indoor temperature sensor is not connected or there is a wiring short. This is about a remote wired sensor on the S terminals, not the sensor built into the thermostat (that is alert 173). Resideo's recommended action is to contact your heating or cooling professional for assistance.
Likely causes
- Wired indoor temperature sensor not connected — Resideo's published cause for 177
- A short in the wired indoor sensor's wiring — Resideo's other published cause for 177
How to fix it — step by step
- Turn power to the HVAC system OFF at the breaker or furnace switch before you pull the thermostat off its wall plate or touch any wiring — that is the makers' own warning on this work.
- Locate the wired indoor sensor (the remote room sensor wired back to the thermostat's S terminals) and confirm it is still mounted and its cable is undamaged where you can see it — a sensor knocked off or a cable cut during other work produces exactly this alert
- Do not open the thermostat wiring yourself beyond looking: the two candidate causes Resideo names — disconnected sensor or wiring short — are distinguished by testing the sensor circuit, which is professional work
- The pinpoint is the wired indoor sensor circuit: sensor disconnected or its wiring shorted. Contact a heating/cooling professional, and report alert 177 and whether any work was done near the sensor or its cable
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Wired indoor temperature sensor.
Parts that commonly fix the 177 code
- Wired indoor temperature sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Honeywell manual is on Honeywell's support site — you'll need your model number.
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.