CodeWhat it meansCheck first
164On a Honeywell T6 Pro Smart, alert 164 means 'Heat Pump Needs Service': the thermostat is reporting that the…Heat pump fault or degraded heat-pump operation detected/reported to the thermostat —›
168On a Honeywell T6 Pro Smart, alert 168 means 'WiFi Radio Error': the wireless module isn't operating and…Failure of the thermostat's Wi-Fi radio / wireless module — Resideo's published meaning›
170On a Honeywell T6 Pro Smart, alert 170 means 'Internal Memory Error': the thermostat's memory has encountered…Internal memory error inside the thermostat — Resideo's published meaning for 170›
171On a Honeywell T6 Pro Smart, alert 171 means 'Set the Date and Time': set the time and date on the thermostat…Date and time not set on the thermostat — Resideo's published meaning for 171›
173On a Honeywell T6 Pro Smart, alert 173 means 'Thermostat Temperature Sensor Error': the temperature sensor on…Failure of the thermostat's built-in temperature sensor — Resideo's published meaning›
175On a Honeywell T6 Pro Smart, alert 175 means 'AC Power Resumed': AC power to the thermostat has been restored…AC power to the thermostat was lost and has now been restored — Resideo's published›
177On a Honeywell T6 Pro Smart, alert 177 means 'Indoor Temperature Sensor Error': the wired indoor temperature…Wired indoor temperature sensor not connected — Resideo's published cause for 177›
178On a Honeywell T6 Pro Smart, alert 178 means 'Outdoor Temperature Sensor Error': the wired outdoor…Wired outdoor temperature sensor not connected — Resideo's published cause for 178›
399On a Honeywell T6 Pro Smart, alert 399 means 'No Internet': the chart says the internet connection has been…Internet connection lost while the thermostat remains powered — Resideo's published›
400On a Honeywell T6 Pro Smart, alert 400 means 'No WiFi Signal': the WiFi signal has been lost, and the fix is…Wi-Fi signal to the thermostat lost — Resideo's published meaning for 400›
508On a Honeywell T6 Pro Smart, alert 508 means 'WiFi Not Configured': download the Resideo App and follow the…Wi-Fi has never been configured on this thermostat, or its Wi-Fi credentials were reset›
Blank ScreenA Honeywell T6 Pro Smart with a blank screen has lost its power supply. This model requires 24 VAC power via…Tripped breaker or blown fuse connected to the heating/cooling system — the first check›
Not CoolingA Honeywell T6 Pro Smart that will not cool: the troubleshooting for 'heating or cooling system does not…System mode not set to Cool, or the cool setpoint not below the indoor temperature›
Not HeatingA Honeywell T6 Pro Smart that will not heat: for 'heating or cooling system does not respond', start at the…System mode not set to Heat, or the heat setpoint not above the indoor temperature›

All Honeywell thermostat models & codes →

Looking for a part?

Once you know the part you need, browse Honeywell T6 Pro Smart replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.