What this problem usually means

'Motor Will NOT Start' — terminal board connections must agree with the wiring diagram on the pump data plate, the pump must be wired for the available field supply voltage, check for improper or loose wiring, open switches or relays, tripped breakers or blown fuses, and check the motor shaft turns freely by hand — and the display branch defines the modern version of this fault: a blank display on a Hayward VS pump is not automatically a dead pump, because the display WILL be blank when the pump is connected to a Hayward automation control (the automation owns the interface), and the blank-display flow ends at a voltage test at the display plug: verify the display wires are securely connected to the RS485 bus with dip switches 1 and 2 ON, then check for 12 VDC across the red and green wires at the display — 12 VDC present means replace the display; absent means replace the power end. A pump that hums but does not start is a different fault (jammed impeller or a seized shaft), and a pump whose speeds are programmed to 0 RPM will sit silent with a live display — the TriStar VST guide lists restoring factory settings for exactly that.

Likely causes

  1. No power — tripped breaker/GFCI, open switch or relay, loose or incorrect wiring at the terminal board
  2. Pump wired for the wrong field supply voltage (the VS drive is dual-voltage; the wiring must match the supply)
  3. Display blank because the pump is slaved to a Hayward automation control — normal, not a fault
  4. Display itself failed — proven by 12 VDC present at the display plug
  5. Drive/power end failed — proven by 12 VDC absent at the display plug
  6. Speeds programmed to 0 RPM (display alive, pump silent)
  7. Motor shaft obstructed or impeller jammed (hum, no start)

How to fix it — step by step

  1. Read the display state first, because it splits the fault in three. Display lit with a message: the pump has power — read the message and check the programmed speeds are not set to 0 RPM; if they are, restore the factory settings. Display blank: continue. Pump humming: skip to step 5.
  2. If the pump is connected to a Hayward automation system (OmniLogic and family), a blank pump display is the expected state — Hayward's guide states it outright: the display will be blank when the pump is connected to a Hayward automation control. Control and diagnose the pump from the automation panel instead; a pump that runs from the panel was never faulty.
  3. Work the supply in this order: breaker (fully off, then on — VS pumps are commonly on GFCI breakers, and a tripped GFCI is silent), any switch or relay in the run, and then, with power OFF at the breaker, the terminal board: connections must agree with the wiring diagram on the pump's data plate label, be secure, and be wired for the field supply voltage actually present. A pump moved, replaced or re-wired onto the other voltage is the classic dead-on-arrival.
  4. With power still off, check the shaft: the test is to verify the motor shaft spins freely by hand (clockwise). A shaft that will not turn is a mechanical seizure or a jammed impeller — that is a pump-end fault for a qualified repairer to open, not an electrical one.
  5. Hum but no start, power proven: this is a jammed impeller — debris in the pump. Do not let it sit humming; switch it off. Clearing the impeller means opening the pump, which is work for a qualified repair professional.
  6. Blank display, no automation, supply proven: the pinpoint test — verify the display's wires are securely connected to the RS485 bus and dip switches 1 and 2 are ON, then measure at the display plug: 12 VDC across the red and green wires means the drive is feeding the display and the display itself has failed — replace the display. No 12 VDC means the drive is not feeding it — replace the power end. That single measurement is the whole diagnosis; hand it to your pool service company in exactly that form if you do not meter it yourself. → Shop the display (user interface) at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $300–$700

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Hayward manual is on Hayward's support site — you'll need your model number.

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Hayward Pool pump problems

See all Hayward pool pump codes & guides →