Generac Guardian Air-Cooled with Evolution Controller Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 13 problems covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

ProblemWhat it meansCheck first
Auxiliary Shutdown 2800An auxiliary shutdown switch, the emergency stop, has been activated and is preventing the generator from…External auxiliary shutdown switch on the back of the generator left open›
Controller FaultThe Guardian chart lists CONTROLLER FAULT as an alarm with no code number. The controller itself has an…Internal controller fault›
High Temperature 1400The engine has overheated and shut down, codes 1400 and 1401, with a red light. Air-cooled units reject heat…Obstruction to intake, exhaust or rear ventilation around the unit›
Low Oil Pressure 1300The low oil pressure sensor has shut the engine down because oil pressure is inadequate, with a red light. In…Oil level low from consumption›
Overcrank 1100The engine turns over but will not start. The controller cranks the engine 5 times, and if it still has not…Fuel shutoff valve is OFF, so no fuel reaches the engine›
Overload Remove Load 2100Electrical load demand exceeds the generator rated capacity, codes 2100 through 2103, with a red light. The…Total simultaneous load above the generator rated capacity›
Overspeed 1200The controller detects engine RPM that is too high and shuts the unit down with a red light. Codes 1200…Lean fuel condition›
Overvoltage 1800The Guardian chart lists 1800 as an OVERVOLTAGE alarm. Output voltage has risen above the rated range and the…Voltage regulation fault inside the controller and alternator system›
RPM Sensor Loss 1500The controller does not detect a valid RPM signal during starting, or loses a valid RPM signal while running…Weak or bad battery, or corroded and loose battery cables and terminals›
Runs RoughThe engine starts but runs rough, hunts, or fluctuates audibly in speed, and may then shut down on…Fuel supply that cannot keep up: shutoff valve partly closed, LP level low, or a›
Starts Then StopsThe engine starts, then shuts down unexpectedly while running, and the controller records the reason. Read…Sudden large load change or overload pulling the engine down while running›
Underspeed 1600Engine speed is too slow, codes 1600 and 1603, with a red light. The engine is being dragged down, most often…Overload: demand exceeds rated capacity, including appliance startup surges 3 to 4›
Undervoltage 1900The generator is not producing proper voltage, codes 1900 through 1906 on Guardian units, with a red light.…Wrong fuel selection in the controller or wrong fuel jet position for the fuel in use›

All Generac generator models & codes →

Looking for a part?

Once you know the part you need, browse Generac Guardian Air-Cooled with Evolution Controller replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.