Bryant Furnace 46.1 Error Code

What the 46.1 code means

Momentary loss of power on Bryant furnaces with a 3-digit status display. The LED flashes major code 46 while the display reads 46.1: heating stopped because of a brief power interruption and restarts once the power fluctuation is resolved. This is a status code, not a failure.

Likely causes

  1. Brownout or brief utility power interruption
  2. Loose 115 V connection or failing door switch (if it happens often with no outage)

How to fix it — step by step

  1. No action is needed if you just had a power blip - the furnace restarts by itself
  2. Check the furnace breaker is fully seated and the service switch is firmly on
  3. Note how often it happens
  4. If 46.1 appears often with no utility outages, have a technician check for a loose power connection

Parts that commonly fix the 46.1 code

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.