Bryant Furnace 12 Error Code

What the 12 code means

Blower on after power up on most Bryant furnaces: if power is restored while the thermostat is calling for heat, the blower runs for about 90 seconds - normal operation, not a fault. Note that on Bryant variable-speed models such as the 355MAV, code 12 instead means blower calibration lockout (calculated blower RPM out of range on two successive attempts; see code 44).

Likely causes

  1. Power was interrupted and restored during a call for heat
  2. On variable-speed models: blower speed calculation out of range, often from high duct static pressure

How to fix it — step by step

  1. On a standard model, wait about 90 seconds - the blower should stop on its own
  2. Confirm the thermostat is set to Heat and the furnace runs a normal cycle
  3. Replace a dirty air filter, which also helps a variable-speed blower calibration fault
  4. If 12 repeats with no power outages, or your furnace is a variable-speed model, call a technician

Parts that commonly fix the 12 code

This fault usually does not need a replacement part - the fix is in the steps above. If your machine does need a part, start with the link above.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.