Bryant Furnace 31.2 Error Code

What the 31.2 code means

Open secondary pressure switch on Bryant furnaces with a 3-digit status display, such as the 912SE. The LED flashes major code 31 while the display reads 31.2: the secondary (high-heat) pressure switch did not close, or reopened, when the control needed it.

Likely causes

  1. Restricted vent or blocked intake/exhaust termination
  2. Plugged condensate drain
  3. Disconnected or obstructed pressure tubing
  4. Defective inducer motor
  5. Defective pressure switch

How to fix it — step by step

  1. Check the outdoor intake and exhaust pipes for snow, ice, leaves or a nest and clear any blockage
  2. Check the condensate drain line and trap for a clog
  3. Replace a dirty air filter
  4. If the code returns, call a technician - never jumper a pressure switch

Parts that commonly fix the 31.2 code

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.