Wayne Plumbing Won't run
What this problem usually means
The pit fills and the pump never starts. For submersible sump pumps, electrical supply comes first — a blown fuse, or line voltage too low (under 108 volts, which points at wiring size) — ahead of the float switch that turns the pump on at roughly 9 inches of water and off at roughly 4.
Likely causes
- Blown fuse or tripped breaker on the pump's circuit
- Low line voltage — if it measures under 108 volts, the wiring size needs checking
- Float switch not being lifted (water below the roughly 9-inch cut-in level) or obstructed
- Pump not on a dedicated circuit, or run from an extension cord (Wayne prohibits both)
How to fix it — step by step
- Safety first: never touch the pump, the motor, the water or the discharge piping while the unit is connected to power, and never handle it with wet hands or while standing on a wet surface — disconnect power before any inspection
- Check the fuse or breaker for the pump's circuit, and confirm the pump is on its own dedicated circuit with no extension cord — a dedicated circuit is required and extension cords are prohibited
- Check the water level: Wayne's factory switch turns the pump on at roughly 9 inches of water and off at roughly 4 inches. A pit below cut-in is not a fault — add water to test
- Lift the float by hand (power connected only for this test, hands dry): if the pump starts, the switch works and something was holding the float — clear debris and confirm the pump sits on a solid, level foundation (use a solid base, not clay, earth, gravel or sand, which let the pump shift and jam the float)
- If the circuit has power and the float is lifted and free and the pump still will not run, check line voltage if you have a meter: under 108 volts points at undersized wiring, an electrician's fix. Voltage good and still dead is the motor — replace the pump. Let a pump that has been running sit at least two hours before servicing it; the oil inside stays hot and pressurized
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the float switch.
Shop the float switch at Amazon
Also tied to this fault: sump pump - Shop at Amazon
Parts that commonly fix it
- float switch$10–$60Shop at Amazon
- sump pump$100–$350Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.