Ryobi Riding mower RY48130 2 Red Flashes
What this problem usually means
Two red flashes on the RY48130's Delta-Q charger is a Battery Voltage Fault: the installed batteries are below 36V or above 67.2V - too discharged, or overcharged, for the charger to start.
Likely causes
- Battery pack voltage below 36V (deeply discharged)
- Battery voltage above 67.2V (overcharged)
How to fix it — step by step
- Charge the batteries by another means to bring them up to 36V, or run the mower to bring an overcharged pack down below 67.2V, per the service manual.
- If the pack repeatedly falls below 36V, one or more batteries in the series string is failing - have the pack tested.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Battery.
Also tied to this fault: Charger - Shop at Amazon
Parts that commonly fix it
- Battery$50–$150Shop at Amazon
- Charger$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.