Resideo Carbon monoxide detector CO9B10D / CO5-B10D 3 Chirps Every Minute

What this problem usually means

Three chirps per minute is the malfunction signal on these Resideo carbon monoxide alarms. The alarm has detected an internal fault; replace the alarm.

Likely causes

  1. An internal malfunction in the alarm

How to fix it — step by step

  1. Confirm the signal at the unit: three chirps per minute is this model's malfunction signal — 'THREE CHIRPS/MINUTE – MALFUNCTION – REPLACE ALARM'. (Five chirps per minute on the same models is the end-of-life signal instead.)
  2. Locate the alarm to work on it: these models are wall-mounted or sit on a tabletop (no more than 3 feet from the floor), one on every level and in every bedroom. There is nothing to open and no battery to try first: the unit is sealed with no serviceable parts and a non-replaceable battery built for its 10-year life.
  3. Replace the alarm: take the old unit off its wall mount or tabletop spot, deactivate it (break the deactivation tab and slide the switch to DEACTIVATE — once deactivated it cannot be reactivated), and install the new CO alarm in the same location, moving its activation switch to ON and pressing and holding Test to confirm it is activated.
  4. Verify the fix: the new alarm should sit in normal standby showing the temperature on its digital display, with no chirps. A weekly test thereafter is the check — a unit that fails to test correctly is replaced, since a malfunctioning alarm cannot alert you to CO.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $35–$100

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Resideo Carbon monoxide detector CO9B10D / CO5-B10D problems

See all Resideo CO9B10D / CO5-B10D codes & guides →