Reset or hush a Kidde smoke / CO alarm
Kidde alarms put three different jobs on one button - Test/Reset/Hush - and which job a press does depends on what the alarm is doing at that moment. Silencing is not resetting: Hush only quiets a smoke alarm for a few minutes, while a reset makes the unit clear its memory and start measuring again. Knowing which one you did tells you whether the alarm is actually watching the air again.
First checks: these apply to every brand
- Silence a smoke alarm: Hush — While the alarm is sounding for smoke, press the Test/Reset/Hush button on the front of the unit. If the smoke is not too dense, the alarm silences at once; voice models announce "HUSH MODE ACTIVATED" and the green LED flashes every 2 seconds. The unit is desensitized, not off: Hush lasts about 9-10 minutes, then the unit resets itself ("HUSH MODE CANCELLED") and alarms again if smoke is still present. Pressing the button again ends Hush early. Dense smoke overrides Hush - if the alarm will not hush, or hushes and immediately re-alarms, treat it as real smoke and get out.
- Reset after a carbon monoxide alarm — Pressing the same button during a CO alarm does a different job: it silences the alarm and resets the unit's CO measurement - the alarm clears its accumulated reading and starts checking the air again from zero. If CO is still present it will alarm again; on current models a re-alarm within about 6 minutes means high CO levels - move to fresh air and call 911. A CO alarm that keeps re-alarming after a reset and ventilation is not a nuisance alarm: leave and call the fire department from outside.
- Clear the alarm memory (the flashing green light) — After an alarm event, the unit's green LED flashes every second to show it alarmed - on an interconnected system, the flashing unit is the one that triggered, which is how you find the source. Pressing Test/Reset clears the alarm memory and stops the flash; that press is the reset. On interconnected hardwired systems, pressing the button on the initiating unit (the one flashing every second) also silences all the other units for about 8-10 minutes.
- Read and reset the peak CO level (display models) — Display models remember the highest CO level recorded since the last reset. Press the button once to view the peak level (a peak is stored when CO reached 100 PPM or more). Pushing the button resets that memory to zero - and the memory also resets any time the unit loses power, so a peak reading disappears after a battery change or an outage.
- Silence a low-battery chirp — The button also works as a Low Battery Hush: one press temporarily silences the low-battery chirp so you can sleep - but the chirp is the message, so replace the battery promptly (on sealed 10-year battery models, the whole unit is replaced). Hushing the chirp repeatedly without changing the battery leaves you unprotected when the battery dies.
- When it will not reset: end of life — Smoke and CO alarms have a 10-year working life. A unit that keeps re-alarming in clean air, shows "End" on the display (Nighthawk), sounds the end-of-life signal, or will not stay reset is finished - the button can hush an end-of-life signal only temporarily. Check the manufacture date on the unit's label; at 10 years, or whenever a unit will not stay reset, replace the alarm rather than resetting it again.
Parts that commonly fix it
When to call a pro: Leave and call 911 or the fire department from outside if a CO alarm re-alarms after a reset - never keep resetting a CO alarm that comes back. Replace any alarm that has reached 10 years from its manufacture date, or that will not stay reset in clean air.