Reset a furnace
A furnace reset is a power cycle: one minute off, back on, one retry. It genuinely clears faults that were caused by a momentary condition, such as a gust down the vent or a sluggish drain. But furnaces also reset themselves in ways worth understanding, and one switch on a furnace must never be 'reset' as a shortcut. This guide is the reset, its limits, and how to read what the retry tells you.
First checks: these apply to every brand
- Clear the cheap causes before you reset anything — A reset into the same blocked condition just re-posts the code. First, go outside and clear both PVC intake and exhaust pipes of snow, ice, leaves or a nest (only what you can safely reach); check the condensate drain line and trap at the furnace for a clog or standing water; replace the air filter if it is dirty.
- The power-cycle reset: one minute off, one retry — Turn power off for one minute, then back on, and call for heat once. Listen for the inducer (the small exhaust fan) starting. That sound is the checkpoint: inducer running means the control accepted the reset and is proving draft. Note whether the code returns before ignition on that retry; if it does, the fault is still physically present.
- Know the resets the furnace does itself — Two automatic behaviours explain 'it fixed itself': a limit switch resets itself as the furnace cools, so a furnace that later restarts on its own was stopped by the limit, which is an airflow problem, not a dead furnace. A limit lockout (code 13) also resets itself after 3 hours. A furnace that needed the night to recover is telling you it overheated, and the filter and registers are where that story starts.
- Never just reset a flame rollout switch — The flame rollout switches are the small round discs with a reset button on top, mounted on the burner box above the burners. If you find one popped, do not press it. That switch is manual-reset by design so the cause gets found first. A popped rollout button confirms flame escaped the burner compartment, and relighting into that condition is how furnaces get dangerous.
- Read the retry, then stop — If the code returns before ignition after one clean retry with vents, drain and filter cleared, further resets only repeat the control's timeouts. Stop there and call a technician, and hand them the useful sentence: the code, that it returns before ignition, and that the vents and drain were already cleared. That points them straight at the inducer, the pressure tubing and the switch.
Parts that commonly fix it
- air filter$5–$30Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
When to call a pro: Call a technician, and do not reset, if a flame rollout switch has tripped, if you smell gas at any point, or if the code returns before ignition after one proper retry with the vents, drain and filter cleared.