A fridge should cycle off for real stretches once it is at temperature. One that runs nearly all the time is losing cold, failing to shed heat, or being told the wrong temperature. The causes are mostly shared with the not-cooling guide, but the order differs: on a fridge that holds temperature yet never rests, start with heat rejection and air leaks.
First checks: these apply to every brand
- Dirty condenser coils: the most common cause — The condenser sheds the fridge's heat, and a coil matted with dust and pet hair cannot. Unplug the fridge, remove the rear or front grille, and brush and vacuum the coils. This is the first check because it is the most common cause and because a fridge that has run hot for months may settle back to normal cycling within a day of cleaning. The coil-cleaning guide on this site has the full procedure.
- Door gaskets and doors that do not quite close — Run the paper test around both doors: close the door on a sheet of paper at intervals around the gasket; it should drag firmly everywhere. A spot with no drag is an air leak that runs the compressor endlessly. Warm a warped gasket section with a hair dryer and reshape it, clean sticky residue off the sealing faces, and check for a door sagging on its hinges or food pushing it ajar. A torn gasket is replaced.
- Blocked vents and an overloaded freezer — Cold air circulates from the freezer; vents buried under food, or a freezer packed so tightly that air cannot move, leave the fresh-food section warm while the compressor never rests. Clear the vents at the back and sides of the freezer and leave space for air to return. Temperatures should be verified with a thermometer: 0 degrees F in the freezer and about 37 in the fresh-food section.
- Condenser fan and evaporator fan — With the fridge running, both fans should be turning. The condenser fan (beside the compressor, reached from the rear) that has stopped leaves the compressor hot and the run times endless; check for obstructions, then test the motor for continuity if it will not turn with power applied by a running compressor cycle. An evaporator fan that has failed shows frost patterns and warm fresh-food temperatures instead, which the not-cooling guide covers.
- Defrost failure: frost doing the damage quietly — Pull the freezer's rear panel if run times stay long: a solid slab of frost on the evaporator strangles airflow and forces constant running. The defrost system's heater, termination thermostat and timer or control are tested in that order, and the defrost branch of the not-cooling guide carries the procedure. A manual defrost that fixes running for a week before it returns confirms the system, not the charge.
- Low charge and a weak compressor: the terminal branch — If the coils are clean, the doors seal, the fans run and there is no frost slab, yet the fridge runs constantly and struggles to hold temperature on warm days, the sealed system is the remaining suspect: low refrigerant from a slow leak, or a compressor losing capacity. Both are diagnosed with gauges and are professional work; a fridge at this branch is also where age and repair cost honestly enter the decision.
See the run-time checks for your exact model
The checks above fix most cases. For the causes, codes and parts specific to yours, pick your brand:
Parts that commonly fix it
- door gasket$110–$190Shop at Amazon
- condenser fan motor$65–$165Shop at Amazon
- defrost heater$40–$110Shop at Amazon
- defrost thermostat$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
When to call a pro: Call a pro if the sealed system is implicated (low charge or a weak compressor), or if the defrost fault is in the control board rather than the heater or thermostat.