Pool pump won't prime

A pool pump moves water, not air. Priming is filling the pump and its suction line with water so the impeller has something to throw; a pump that will not prime is almost always short of water or drawing air somewhere on its suction side. Hayward and Pentair publish the same core procedure and the same short list of causes, and nearly all of them are owner checks that need no parts and no teardown. Work them in order: level, pot, lid seal, baskets, valves, then the air-leak hunt.

First checks: these apply to every brand

  1. Safety first, and never let it run dry — Power off at the breaker before opening the pump, close the suction and outlet valves, and release all pressure through the filter's air relief valve. Two warnings from the manuals govern everything after: never run the pump dry (the water cools and lubricates the mechanical shaft seal, and a dry run damages it), and treat a pump that just failed to prime as pressurized and hot, so let it cool before the lid comes off.
  2. Check the pool water level before touching the pump — About halfway up the skimmer opening (Pentair's wording; Hayward: above all suction openings). Below that, the skimmer draws air and the pump loses prime no matter what you do at the equipment pad. Top the pool up first; it is the cheapest fix on the list.
  3. Fill the strainer pot with water — Lid off (turn the clamp/lid or cover counter-clockwise), then fill the housing/pot with water to the level of the suction pipe (Hayward) / fill the pot and volute to the inlet (Pentair). The exception both makers state: in a flooded-suction setup, where the water source is higher than the pump, the pump primes itself when the suction and discharge valves are opened.
  4. Clean, inspect and seat the lid O-ring — The lid seal is the most common air leak on the pump itself. Clean the O-ring/gasket and its seat, check for cracks, flattening or pinching, and reseat it. One brand difference that matters: Hayward says clean and lubricate the cover O-ring; Pentair's IntelliFlo O-ring is internally lubricated and Pentair says do not lubricate it. Both agree on the ending: lid back on, tightened by hand only, never with a wrench. A damaged gasket is replaced, not coaxed.
  5. Empty the skimmer basket and the pump strainer basket — A clogged basket starves the suction side and shows up in both makers' charts as a priming failure. Rinse the pump basket rather than striking it clean (Hayward), and make basket cleaning part of the routine: a basket that keeps loading up will keep costing prime.
  6. Open every valve and bleed the air out — All suction and discharge valves open and unobstructed, the filter air relief valve open, then start the pump and stand clear. Leave the relief open until it passes a steady stream of water with no air in it, then close it. Air bubbles still showing in the strainer pot or at the pool returns mean air is still getting in on the suction side: that observation is the fork between 'not primed yet' and 'air leak'.
  7. Give it its priming time, then stop — Priming is not instant: Hayward allows up to five minutes on a single-speed pump and up to fifteen on its variable-speed models; Pentair's variable-speed drives run a timed priming cycle and stop with a PRIME ERROR / Priming Failure alarm if they never detect prime. If the pump has not primed inside its window, switch it off at the breaker and diagnose; leaving it running dry only burns the shaft seal.
  8. Hunt the suction-side air leak — With water in the pot and the lid sealed, the remaining air is entering through the suction piping: joints, unions and the valve glands on suction gate valves (Pentair's chart names the valve glands specifically). Hayward's split test settles which side of the pump the fault is on: block the suction close to the pump and see whether it develops a vacuum. Vacuum develops: the leak or blockage is in the suction line or strainer. No vacuum with a full housing: tighten the suction-side bolts and fittings, then suspect the pump itself.
  9. Check the impeller for a clog — Power off, and on Pentair's procedure: remove the bolts holding the housing (strainer pot/volute) to the seal plate, slide the motor and seal plate away, and clear debris from the impeller; a clogged impeller presents as exactly this, priming failure with weak or no flow. Reassemble with the diffuser and O-rings seated and the bolts secure, then prime again from the pot-fill step.

Parts that commonly fix it

Parts run $10–$45

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a pool service tech when the pump still will not prime with the pot full, the lid sealed, the suction line proven tight and the impeller clear: what is left is inside the pump (a worn shaft seal that can no longer hold vacuum, replaced in both halves) or in the motor and drive, and variable-speed drive alarms beyond priming (over-current, overheat) are drive work, not priming work.