Pilot light won't stay lit
On a standing-pilot water heater, the pilot stays lit only while its flame heats the thermocouple enough to hold the gas valve open. The diagnosis splits cleanly on when it goes out: the moment you release the knob points to the thermocouple circuit, while hours or days later points to air, drafts or gas supply. This guide is mostly about knowing which you have, because the gas parts themselves are pro work.
First checks: these apply to every brand
- Safety first: one relight, exactly by the label — If you smell gas, stop: leave the house and call the gas utility or 911 from outside. Otherwise, relight once, following the lighting instructions printed on the heater's own label exactly. Model steps differ, and the commonest failed relight is releasing the knob before the thermocouple has had its 30 to 60 seconds in the flame to heat up.
- Note exactly when it goes out — Goes out the instant you release the knob, even after a careful relight: the thermocouple is not producing or passing its signal, because it is dirty, loose at the gas valve, slipped out of the flame, or worn out. Goes out later, after heating cycles, overnight, or on windy days: the flame itself is being lost, which is drafts, combustion air or venting. This timing observation is the whole diagnosis; make it before anything is touched.
- Look at the pilot flame — A healthy pilot is a steady blue flame enveloping the top of the thermocouple tip. A small, yellow, lazy or wavering flame cannot heat it properly. That pattern means a dirty pilot orifice or restricted pilot tube, or too little gas reaching it. Flame shape is evidence you can gather from outside the burner chamber; cleaning the orifice is gas work and belongs to a technician.
- Check for drafts and blocked combustion air — Pilots that die when a door opens, a fan runs or the wind picks up are being blown or starved. Clear stored items away from the heater, and check the air intake screen at the base, where on FVIR models a screen clogged with lint and dust starves the burner of air until the pilot fails. Restore the air supply and the clearance the manual specifies.
- Check the vent and the other gas appliances — Soot, scorch marks, a rusted or disconnected flue, or a pilot that dies when other appliances fire, points to venting or gas supply: a downdraft pushing exhaust back down, or pressure too low to sustain the flame. Confirm the gas valve to the heater is fully open and note whether other gas appliances are also misbehaving; a house-wide pattern is a utility problem.
- Accept the parts verdict: thermocouple, then gas control valve — If the flame is strong and blue, the air supply is clear and the pilot still dies on release, the thermocouple (or thermopile on millivolt models) has failed, and it is the most common part for this symptom. If a new thermocouple does not hold it, the gas control valve itself is the fault. Both are gas-train parts: replacement is a licensed plumber's job in most places, and repeated relighting is not a substitute.
- The millivolt test: putting a number on the thermocouple — The parts verdict above has a measurement behind it. A thermocouple (or the thermopile on millivolt systems) generates the current that holds the gas valve's magnet open, and it is tested with a meter on the millivolt scale at the valve terminals: the Rheem procedure behind this site's Rheem pages expects roughly 10 millivolts or better under load from a healthy thermocouple with a good pilot flame on it. A reading well under that, with the pilot flame properly enveloping the tip, condemns the thermocouple. A healthy reading with a pilot that still drops out moves the verdict to the valve's magnet, which is gas work and a technician's.
Parts that commonly fix it
- thermocoupleShop at Amazon
- thermopile$25–$80Shop at Amazon
- gas control valve$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
When to call a pro: Call a licensed plumber or gas technician for the thermocouple, pilot assembly, venting or gas valve work itself. This guide's owner checks are observation and relighting only. Call the gas utility from outside immediately for any gas smell, and treat a carbon monoxide alarm as an emergency, not a symptom.
Look up a code for your model
Finished the checks above and you have a code to look up? Pick your brand to see what its codes mean: