No hot water at all is a supply failure, not a capacity failure: the heater has lost its power, its flame, or its one working heating path. Start with power and the reset limit on electric models and the pilot on gas models. Split by fuel first, because the two diagnoses share almost nothing.

First checks: these apply to every brand

  1. Split by fuel, and check the obvious at the taps — First confirm the cold taps run and the hot taps run cold. A single odd fixture is a fixture problem, not the heater. Then identify your heater: electric tank, gas tank, or tankless. A tankless with no heat and an error code belongs to the tankless guide; this guide covers tank heaters, electric checks first, then gas.
  2. Electric: reset the breaker — An electric heater has a dedicated double breaker, and a tripped one leaves the tank full of water that simply cools. Reset it fully off, then on. A breaker that trips again as the heater draws power is reporting a grounded element or a wiring fault. Do not keep resetting it; that is the diagnosis, and it needs a technician.
  3. Electric: press the high-limit reset (ECO) — Behind the upper access panel, above the upper thermostat, sits a red reset button, the manual-reset limit that cuts all power if the water overheats. With the breaker OFF before any panel comes off, press it firmly: a click means it had tripped. Power restored and hot water back is a result, not a cure. A limit that trips again means a thermostat or element is misbehaving and needs finding.
  4. Electric: the upper element decides everything — Standard electric tanks heat the top first, and only then hand over to the lower element, so a burned-out upper element (or failed upper thermostat) means no hot water at all, while a failed lower element still gives a short supply. With power off and wires lifted, an element tests with a meter: a healthy one shows resistance (roughly 10 to 30 ohms on common elements); an open reading is burned out and is replaced. This is the single most common part behind a stone-cold electric tank.
  5. Gas: check the pilot and the status light — Look at the pilot through the sight glass, or read the gas control's status light: no pilot and no light means the flame is out and the main burner will never fire. Relight once, exactly by the label on the heater. A pilot that will not stay lit has its own guide and its own verdict, thermocouple first, and repeated relighting is not a fix.
  6. Gas: confirm the gas supply and the control setting — Check the gas valve on the pipe to the heater is fully open, other gas appliances work, and the control knob is set to a real temperature, not Vacation, Pilot or Off, where heaters are often left after holidays or plumbing work. A setting near 120°F is the normal target. If you smell gas at any point: leave, and call the utility from outside.
  7. Both fuels: rule out a leak or a flood of cold demand — A tank that has leaked empty, or is leaking fast, cannot give hot water. Check around the base and in the drain pan. And a heater that was drained or refilled for plumbing work needs time: a full tank takes an hour or more to recover, so a recently refilled heater that is merely lukewarm is working, not broken.
  8. Gas, electronic ignition: the branch past the pilot — Tank heaters with electronic ignition have no standing pilot to check, and their no-heat branch is different: a hot-surface or spark igniter lights the burner on demand, a flame sensor proves it, and an FVIR thermal switch can open after an overheat or flammable-vapour event and shut the system down until it is reset or replaced per the maker's procedure. The status light on the gas control reports the system's own verdict as a flash pattern, and your brand's pages on this site decode it. An igniter that never glows and a control showing no fault at all is where this branch hands off to a technician with the model's service manual.

Parts that commonly fix it

Parts run $10–$50Typical pro repair $228–$1,017Fixing it yourself typically saves $178–$1,007

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a plumber or electrician if the breaker or high-limit keeps tripping, if element or thermostat testing is beyond you, because access panels on an electric heater expose 240-volt terminals, or for any gas fault past relighting. Any gas smell means leave the house and call the utility first, troubleshoot later.

Look up a code for your model