Hot tub jets not working

Jets fail as a group (a pump, air lock or valve problem) or one at a time (the jet itself). That split is the whole diagnosis, so establish it first: turn every jet on and note whether the weakness is everywhere or in one seat.

First checks: these apply to every brand

  1. Individual jets turn off: check each jet's face — Most jets adjust or shut off by rotating their face. A single dead jet is usually just turned off, or its internal has unscrewed or clogged with scale and debris. Rotate it fully open; if it stays dead, the jet internal pops or unscrews out (with the pump off) for cleaning or replacement. Jets are brand-and-size specific parts.
  2. Air lock after a drain and refill — Weak or surging jets across the whole tub right after a refill is air trapped in the pump: loosen the pump's union slightly until air hisses out and water appears (power off, towels ready), or run the pump in short bursts per the maker's priming procedure. An air lock left running overheats and damages the pump, so this is done before any longer test.
  3. Diverter and air-control valves — Diverter valves route pump power between seats, so a whole seat group dead with others strong is a diverter sitting between positions or with a failed internal. Work the diverter through its full travel with the pump on low. Air controls add the venturi air that makes jets feel strong; a tub with water flow but no punch often has its air controls closed or their intakes blocked.
  4. Filter and water level: the quiet causes — A clogged filter starves the pump and weakens every jet, and low water lets the pump suck air through the skimmer. Clean or swap the filter and top the water to the maker's line, then retest before condemning a pump. These two causes account for most weak-jet calls.
  5. Pump failure: the group verdict — All jets dead with the pump silent, humming or tripping its breaker is the pump itself: a hum with no start is a failed start capacitor or a seized impeller (scale and debris seize pumps that sat), and a pump that runs with no flow after priming has a broken impeller. Spa pumps and their wet ends are replaceable parts, fitted with the power isolated and the tub drained below the unions.

See the jet checks for your spa's pack

The checks above fix most cases. For the causes, codes and parts specific to yours, pick your brand:

Parts that commonly fix it

Parts run $25–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a pro if the pump's electrical supply or capacitor is in question inside the equipment bay, or if a breaker trips when the pump starts: water and mains electricity meet there.