Heat pump not heating

A heat pump's normal behaviour imitates failure: its supply air is warm, not hot, and it periodically blows cool air while it defrosts itself. The most common real causes are the unglamorous ones: thermostat setting, breaker and dirty filter. Rule out normal, then settings, then ice, in that order.

First checks: these apply to every brand

  1. Measure the vent air before calling it cold — Heat pump supply air in heating mode is about 85 to 100°F. That is body-temperature air that feels cool on skin, compared with 120 to 140°F from a gas furnace. Put a thermometer at a supply register: air in that range, with the room holding or gaining, is a heat pump working normally. Air at room temperature or below, sustained, is a fault. Continue.
  2. Give a defrost cycle time to finish — In cold, damp weather frost builds on the outdoor coil and the system briefly reverses to melt it: vents blow cooler air for a few minutes, the outdoor fan stops, and steam rises off the unit. A typical defrost takes about 5 to 10 minutes, and a demand defrost takes 3 to 5 minutes. Heat that returns on its own was defrost. Cool air that never ends, or an outdoor unit still iced solid an hour later, was not.
  3. Check the thermostat: Heat, AUTO, and the right system type — Set Heat, fan AUTO (fan ON blows unheated air between cycles and feels like no heat), and the setpoint several degrees above room temperature; replace dead thermostat batteries. If the system was recently fitted with a new thermostat and now cools on a heat call, the reversing-valve (O/B) setting is configured backwards. That is an installer setting, and a common cause of exactly that symptom.
  4. Reset the breakers and replace the filter — Heat pump systems have breakers for both the outdoor unit and the air handler; a tripped one leaves half the system running and no heat. Reset fully off, then on. Then check the filter. A dirty filter is one of the most common no-heat causes. It starves airflow, forces the system onto its expensive backup heat, and can trip limits. Fit a clean one.
  5. Read the auxiliary heat honestly — AUX on the thermostat means the electric backup strips in the air handler are helping. That is normal during defrost and in genuinely cold weather, when a heat pump alone loses capacity as temperatures fall. AUX running constantly in mild weather, with the house still losing ground, means the heat pump side is contributing little: the filter above, a dead outdoor fan, low refrigerant or a defrost fault. If the house cannot hold temperature, switch to Emergency Heat so the strips carry it, and book service.
  6. Look at the outdoor unit: ice, fan and clearance — A light, even frost that comes and goes is normal. Thick ice encasing the coil, ice that never melts, or a silent outdoor fan under a running compressor means defrost has failed, which is a sensor, board or fan fault, and the coil can no longer absorb heat. Clear snow, leaves and debris away from the unit, but never chip ice off the coil or pour hot water on it: both damage it. Run Emergency Heat and call a technician.
  7. Accept the sealed-system verdicts — What remains is technician work by law and by physics: low refrigerant from a leak (the system runs nonstop and heats weakly), a reversing valve stuck in cooling (the system cools on a heat call and heats on a cool call), a failed compressor or capacitor, and defrost controls. Refrigerant handling requires certification, and a capacitor can hold a dangerous charge with the power off.

Parts that commonly fix it

Parts run $5–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a licensed HVAC technician for an iced-solid outdoor unit, constant AUX in mild weather, any refrigerant, reversing valve or compressor fault, or a breaker that trips again after one reset. Use Emergency Heat to protect the house, and watch for frozen pipes, while you wait.