Furnace blowing cold air / no heat

Cold air from the vents usually means the blower is running while the burners are off — a setting, an airflow problem, or a safety shutdown — rather than a furnace that has died outright. Start at the thermostat and work toward the furnace.

First checks — these apply to every brand

  1. Check the thermostat settings — Set the thermostat to Heat, a few degrees above the room temperature, and set the fan to AUTO, not ON: with the fan on ON the blower pushes unheated air between heating cycles, which feels like the furnace is blowing cold. If the display is blank or dim, replace the thermostat batteries.
  2. Confirm the furnace has power — Check the furnace's service switch (often a light switch on or near the unit) is on and the breaker hasn't tripped. A blown low-voltage fuse on the control board also leaves the furnace completely dead, and it usually blows because of a short that needs finding.
  3. Replace a dirty air filter — A clogged filter starves airflow, the furnace overheats, and its limit switch shuts the burners off while the blower keeps running to cool down — warm air that turns cold is the classic symptom. Fit a clean filter, open all supply registers and make sure return grilles aren't blocked.
  4. Confirm the gas supply is on — Check the manual gas shutoff valve near the furnace is open, with the handle parallel to the pipe, and that other gas appliances in the home work. If you smell gas at any point, stop, leave the house and call your gas utility.
  5. Clear the outdoor vent and intake pipes — Snow, ice, leaves and nests blocking the PVC intake or exhaust pipes stop the pressure switch from closing, and the furnace won't ignite. Clear anything you can safely reach and try one heat call.
  6. Check the condensate drain (high-efficiency models) — On condensing furnaces, a clogged or frozen condensate drain line or trap backs water up and shuts the furnace down the same way. Clear the line and trap if you can reach them safely.
  7. Watch one ignition attempt, then stop resetting — If the burners light and go out within seconds, the flame sensor is usually dirty; if they never light, the igniter is the usual suspect. Either fault locks the furnace out after a few tries. One power reset (off for 30-60 seconds, then on) is reasonable — repeated resetting is not, and the repair itself is technician work on a gas appliance.

See the fix for your exact model

The checks above fix most cases. For the causes, codes and parts specific to yours, pick your brand:

Parts that commonly fix it

When to call a pro: Call a licensed HVAC technician for anything involving the gas valve, igniter, flame sensor or pressure switch, and never jumper a limit or pressure switch or keep resetting a furnace that locks out.