Change a furnace filter

The furnace filter is the cheapest part in the heating system and the cause of a surprising share of its fault codes: a clogged filter starves airflow until the furnace overheats and its limit switch opens. The filter is the second step in the limit lockout procedure. The job is five minutes, no tools, and the only way to get it wrong is the airflow arrow. For which size and rating to buy, the Filter Finder covers it; this guide is the change itself.

First checks: these apply to every brand

  1. Power off, then find the filter slot — Turn power off at the furnace service switch. The filter lives in one of two places: it slides into a slot in the blower compartment behind the lower front door, or it sits in a rack at the blower compartment or a return-air grille. If you cannot find a slot at the furnace, check the big return grille in the living space before assuming there is no filter.
  2. Pull the old filter and read it — Slide the old filter out and note the size printed on its frame. That printed size, not a measurement, is what you buy. Then hold the filter up to the light. If light barely gets through, or the surface is grey and matted, the filter was overdue; a filter you can see light through evenly has life left, whatever the calendar says.
  3. Fit the new filter with the arrow toward the furnace — Fit the clean filter with the airflow arrow, printed on the frame, pointing toward the furnace. The arrow follows the air: from the return duct, through the filter, into the blower. A filter fitted arrow-out is a restriction the furnace will report as overheating on a long enough cycle.
  4. Restore airflow everywhere, not just at the filter — Close the compartment, restore power, and open every supply register in the house and clear furniture, rugs and boxes away from all return grilles, because the filter is rarely the only restriction. Run a full heating cycle: the furnace should light, run, and satisfy the thermostat. A limit code that returns with a clean filter and open registers has a different cause, and it is technician territory.

Parts that commonly fix it

Parts run $5–$30Typical pro repair $133–$505Fixing it yourself typically saves $103–$500

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a technician if the furnace keeps limit-tripping (Carrier code 13 and its equivalents) with a clean filter and every register open, because the limit or flame rollout switch, blower motor and vent then need testing, and a tripped rollout switch must be diagnosed, never just reset.

Look up a code for your model

Finished the checks above and you have a code to look up? Pick your brand to see what its codes mean: