Central air conditioner not cooling
A central system that runs without cooling has failed at airflow, at the outdoor unit, or in the refrigerant circuit, and the first two are checkable from outside the equipment. Work in that order. Anything involving refrigerant gauges, or opening sealed electrical compartments beyond the disconnect, belongs to a licensed technician; the owner-level tests below are the ones that decide most calls.
First checks: these apply to every brand
- Thermostat, filter and supply air: the free checks — Confirm the thermostat is set to Cool, several degrees below room temperature, with the fan on Auto. Pull the return filter: a filter you cannot see light through strangles airflow enough to stop cooling and eventually freeze the coil, and it is replaced before any other diagnosis. Then feel the supply registers: air moving but warm means the indoor half works and the outdoor half is not (check 2); no air at all means the blower or its control, which the brand pages for your system's codes cover.
- The outdoor unit: is it running at all? — Go outside. A silent outdoor unit with a working indoor blower is usually its disconnect, its breaker, or its capacitor (check 3). A unit whose fan runs but that sounds different, with no compressor hum underneath, is a compressor not starting, again usually the capacitor. A unit choked in cottonwood, leaves or a fence panel cannot shed heat and will cool weakly and trip on hot afternoons: clear at least two feet around it and rinse the coil fins gently from inside out with a hose, power off.
- The run capacitor: the most common no-cool failure — The dual run capacitor in the outdoor unit starts the compressor and the fan, and it weakens with age and heat. The owner-level signs are a bulged top on the can, a humming unit that will not start, or a fan that starts when spun by hand with a stick (power on test, done carefully and never by fingers). The definitive test is a capacitance reading against the microfarad rating on the label, done by a technician with the power off and the capacitor discharged, because the terminals sit in a live compartment. Given the part's cost, most owners book this as the first professional test rather than a guess.
- The contactor: clicks, ants and burnt points — The contactor is the relay that the thermostat's 24-volt call pulls in to power the outdoor unit. A unit that stays silent while the thermostat calls, with power proven at the disconnect, often has a contactor whose coil has failed or whose points are burnt or blocked by insects, a genuinely common find. Contactor replacement is electrical work inside the unit's compartment; the owner verdict is a proven call for cooling with a dead outdoor unit, which is what you report.
- Frozen coil: shut it down and thaw — Ice on the refrigerant lines or the indoor coil means airflow or charge, never a setting. Switch the system to Off and the fan to On, and let it thaw fully (hours, with towels at the air handler) before any restart. A coil that refreezes on a clean filter and open registers has a refrigerant problem, which is licensed work. The frozen-coil guide on this site carries the full sequence.
- Refrigerant and the compressor: the honest end — Air that is cool but never cold enough, run times that stretch all day, and a system that has needed refrigerant before all point at low charge from a leak. Refrigerant is never simply topped up as maintenance: the leak is found and repaired, then the charge is set by measurement. Compressor failure is the other terminal verdict, and on an older system it is where repair-versus-replace is honestly decided.
See the cooling checks for your exact system
The checks above fix most cases. For the causes, codes and parts specific to yours, pick your brand:
Parts that commonly fix it
- run capacitor$5–$35Shop at Amazon
- contactor$10–$35Shop at Amazon
- air filter$5–$30Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
When to call a pro: Call a licensed HVAC technician for refrigerant work, for capacitor or contactor testing inside the electrical compartment, and for any compressor diagnosis.