Air conditioner won't stop running
An air conditioner that never shuts off is usually losing a fight against a dirty filter, a thermostat that keeps calling, or a coil that cannot move heat, rather than running 'too well'. Start with telling a real fault from a hot day.
First checks: these apply to every brand
- First, is it actually a fault? Long runs on the hottest days can be normal — A healthy system cycles about 20 to 30 minutes at a time, two to three cycles per hour. On the hottest days, long runs with very short off-cycles are normal. The system is at its design limit. The fault pattern is different: it runs continuously AND the house is not reaching the set temperature, or it runs when the house is already comfortable. Note which one you have before changing anything.
- Thermostat checks: fan On vs AUTO, then the thermostat itself — Check the fan setting before anything else. On 'Fan: On' the blower runs constantly while the compressor cycles normally. The air from the vents is room-temperature when the compressor is off, so it feels like the air conditioner never stops, but only the fan is running. Set the fan to AUTO, where the blower runs only with the compressor, and the 'fault' may be gone. Beyond the setting, check the thermostat itself: dirty sensors, damaged or loose wiring, or a failing thermostat can call for cooling nonstop.
- Dirty air filter: the most common fixable cause — A clogged filter strangles airflow, so the system has to run longer to move the same amount of heat. The dirty filter is the cause behind most homeowner issues, and replacement is every 30 to 90 days depending on pets, smokers and allergies. The filter is in the return grille or the air handler slot; if you cannot see light through it, it is overdue.
- Outdoor unit runs even with the thermostat off: the contactor — At the outdoor unit, the compressor contactor is the switch that feeds it power. If its contacts have welded themselves closed, the outdoor unit has constant power and runs regardless of what the thermostat asks for. This check is for a professional only, because it involves line voltage at the unit, but it is the pinpoint when the outdoor unit runs with the thermostat set to Off.
- Dirty or frozen evaporator coil — The indoor evaporator coil, clogged with dirt and debris, cannot absorb heat efficiently, so cycles stretch longer and longer and the vents may blow only cool-ish air. Coil cleaning is professional work: electrical shock risk, fins that bend and corrode easily, and household cleaners that can damage the coil. A frozen coil belongs to the same branch. Restricted airflow freezes it, and a frozen coil has almost no capacity, so the system runs forever and cools barely at all; if you see ice, switch the system off, let it thaw, change the filter, and treat a repeat freeze as a service call.
- Never kept up since it was installed: it may be undersized — An undersized system works overtime by definition. It can run all day and still not reach the setpoint on a hot day. Sizing is not square footage alone (insulation, ceiling height, sun exposure and occupants all count, and a dealer sizes with a load calculation), so a system that has never kept up since installation is a sizing conversation, not a repair. The opposite fault is worth separating out while you are here: a system that turns on and off every few minutes, short-cycling, is usually an oversized system or a thermostat sitting in direct sunlight or next to a heat source, and it leaves the house cold and clammy rather than cool.
Parts that commonly fix it
- air filter$5–$30Shop at Amazon
- thermostat$70–$280Shop at Amazon
- contactor$10–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
When to call a pro: Call a pro for a welded contactor, for evaporator coil cleaning (there is a shock risk, and household products and brushes damage the fins), and for a system that still runs long after the filter, thermostat and fan checks. Refrigerant charge and sizing are measured, not guessed. A system that never stops AND never cools is losing capacity somewhere a gauge set has to find.