Air conditioner not cooling

When a window air conditioner runs but the room stays warm, work in this order: settings first, then airflow, starting with the filter and then the coils, then ice, then the window installation and the room's heat load, with the sealed refrigerant system last and reserved for a technician. Work through these checks in that order. Most warm rooms are fixed by the first four. The same sequence covers central systems, which use the same checks.

First checks: these apply to every brand

  1. Prove it is actually in Cool mode, set cold, and give the compressor its three minutes — Set the mode to Cool, not Fan Only, Dry or Energy Saver, and set the temperature to the unit's lowest, then wait about three minutes. Switching modes stops the compressor, and it restarts roughly three minutes after Cool is selected. Run Cooling at 18°C (64°F) for more than 30 minutes before judging the result. Energy Saver and fan-cycling modes switch the fan off with the compressor, so the air between cycles is uncooled room air and the room can feel like the unit has quit. Fan cycling can create exactly that hot-spot effect. If the air turns properly cold under this test, the settings were the fault and nothing is broken.
  2. Clean the air filter: the single most common cause — The filter sits behind the front grille or decorative front. It slides or lifts out by hand, with no tools and no cabinet opening. Wash it in warm water with mild detergent, keeping the water at or below 40°C / 104°F, shake off the water and let it dry completely before refitting, or vacuum it clean. It clogs fast: clean it every two weeks in use, clean it within the last 30 days, and inspect it weekly and clean it at least monthly. Judge the result honestly: a filter you cannot see light through starves the coil of air, which both weakens cooling directly and sets up the icing in the next check.
  3. Clear the front of the unit and aim the louvers into the room — Drapes, blinds or furniture in front of the unit restrict the air it can take in and throw out, so clear the front completely and keep obstacles away from the intake. Keep about 20 cm (8 in) of clear space around the product. Then aim the directional louvers so the cold air is distributed into the room instead of straight at a wall or the floor. Badly positioned louvers are a cause of a room that stays warm while the unit runs.
  4. Look for ice on the coil behind the filter — With the filter out, look at the cooling coil directly behind it. A sheet of ice or heavy frost means the coil has frozen, and a frozen coil passes almost no air. The unit runs, and the room stays warm. The fix is to switch to Fan Only and let the fan melt the ice, then restart in Cool; if it iced overnight at a very cold setting, raise the setting a little. Ice has causes, so read the result: it forms when airflow is restricted (the dirty filter above), or when the unit is run in cool outdoor weather. Do not run cooling below 60°F outside, and capacity is limited and coils ice at or below 70°F. Ice that comes back quickly with a clean filter and warm weather outside is the signature of low refrigerant, which is the pro endpoint below.
  5. Clean the outdoor coil at the back and let the heat escape — Half of a window unit lives outside the window, and the coil at the back is where the room's heat is dumped. A coil matted with dirt, cottonwood or leaves cannot reject heat, so the cold side stops getting cold. Access is external, with nothing to open: vacuum the rear coils with a soft bristle brush, or brush or vacuum them, and the outdoor coil can be gently sprayed with a hose if you can reach it. Keep water off the electrical parts and never bend the fins. While you are back there, check the heat can actually leave: on a double-glazed or storm window, a closed outer window traps the heat and cooling performance deteriorates, so open it.
  6. Seal the window, close the vent, and check the tilt — A window unit cools one sealed box; every gap around it trades cold air for hot. Check the side panels and gaskets: check the side gaskets on both sides of the mounting plate and the window gap insulator fitted to the window height, and check the chassis seal gasket. If it is missing or badly fitted, cooled air escapes and outside air pours in. Close the fresh-air vent control for maximum cooling, and close the room's doors, windows and any open registers, because open doors and windows let the cold air straight back out. Finally check the unit still slopes slightly down toward the outside, the tilt the installers set so condensate drains out the back instead of pooling in the pan.
  7. Give it time, cut the heat load, and check the unit is big enough for the room — A unit can be healthy and still lose to the room. Heat stored in walls, ceiling, floor and furniture has to be removed before the air temperature falls, and starting the unit before the room heats up avoids the worst of it. Cut the load while it works: shade sun-struck glass, run exhaust fans over cooking and showers, and keep heat-producing appliances off during the hottest part of the day. Then consider the sizing question: a room air conditioner is built for one room of a rated size, and an undersized unit runs constantly, blows genuinely cold air, and still never reaches the setpoint. Cold supply air plus a room that cools slowly but keeps creeping down means the unit is fine. The load or the size is the diagnosis.
  8. Pinpoint what is left: compressor that never starts, or a system that runs but cannot cool — What is left after settings, filter, airflow, ice, coils and sealing is inside the sealed cabinet, and the symptoms pinpoint it. Fan runs, settings are right, but the compressor never starts, with no click and change of hum after the three-minute wait, points at the start capacitor, the control or the compressor itself. Air that is only slightly cool with everything clean, especially with ice that keeps returning, is the low-refrigerant pattern: the charge only ever falls because of a leak, and this case needs service for a coolant leak check. Both are sealed-system or electrical work: tell the technician which branch you landed on, compressor never starts, or compressor runs but cannot cool, because that one observation halves their diagnosis.

Parts that commonly fix it

Parts run $5–$30Typical pro repair $450–$2,000Fixing it yourself typically saves $420–$1,995

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a licensed HVAC technician for anything inside the sealed refrigerant system, such as a leak search, a recharge, compressor or capacitor work, and for any fault that survives a clean filter, clear airflow and a defrost with the unit still blowing warm. Stop and unplug the unit at once if cooling trouble arrives with smoke, a burning smell or a damaged power cord. Do not operate a unit in that state at all.

Look up a code for your model

Finished the checks above and you have a code to look up? Pick your brand to see what its codes mean: