Air conditioner leaking water

Air conditioner water is supposed to travel one path: condensing on the evaporator coil, dripping into the drain pan, and leaving through the condensate drain line. A leak means that path failed, and it fails at the drain line first.

First checks: these apply to every brand

  1. Trace the water path first: coil, pan, drain line — All the moisture the system pulls out of indoor air condenses on the cold evaporator coil, drips into a drain pan under the coil, and should leave through the condensate drain line. Water on the floor means that path has failed at one of four places: the line, the coil, the pan or the pump. Work through them in this order, because the first check is the most common cause. Find the indoor unit (air handler or furnace coil) and note where the water appears: under the unit is the pan and line; at the end of a cycle is often a frozen coil thawing.
  2. Clogged condensate drain line: the most common cause — Algae, mold and dust build up in the condensate line until water backs up into the pan and overflows. Find where the drain line exits, usually a white PVC pipe ending outside near the outdoor unit or at a floor drain. Clear it from the outside end with a wet/dry vacuum, or flush it from the access point near the indoor unit. If the water stops and the pan level falls, the clog was the whole fault.
  3. A frozen evaporator coil thawing can flood the pan — A coil that froze into a block of ice melts far more water than the pan and line can handle, and it drips everywhere as it thaws. Switch the system off at the thermostat (fan on is fine) and let it thaw completely before judging anything else. Then find why it froze before it happens again: the next two checks are the usual reasons, starting with the filter.
  4. Check the air filter — A clogged filter starves the coil of airflow, which is what lets it get cold enough to freeze in the first place, and it increases condensation even when nothing freezes. The filter sits in the return grille or the air handler slot. If you cannot see light through it, replace it, and recheck the coil for ice after a day of running.
  5. Inspect the drain pan for cracks and rust — With the system off, shine a flashlight into the pan under the coil. A pan that has corroded or cracked leaks straight through instead of channeling water to the drain outlet. The water appears even with a clear drain line, and it appears under the middle of the unit rather than at the line's end. A cracked pan is replaced, which on most air handlers is a pro job.
  6. If yours has a condensate pump or a float switch — Systems that cannot drain by gravity use a small condensate pump to lift the water out; a pump that has failed, lost power or has a stuck float fills its reservoir and overflows. Many systems also have a float switch in the pan or line that shuts the system down when water backs up. If your air conditioner has stopped AND there is water present, that switch is protecting the ceiling, and clearing the drain (check one) is what resets the situation.

Parts that commonly fix it

Parts run $5–$60Typical pro repair $450–$2,000Fixing it yourself typically saves $390–$1,995

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

When to call a pro: Call a pro if the coil freezes again after a filter change and a thaw (that is refrigerant charge or airflow inside the sealed system), if the drain pan has rusted through, or if water is reaching wiring, the ceiling or a wall cavity. Stop the system and let it dry rather than running it wet.