Pentair Pool pump Won't prime
What this problem usually means
Pentair's IntelliFlo VSF troubleshooting chart lists 'Pump will not prime' with two root causes: an air leak in the suction, or not enough water (variable-speed drives may show PRIME ERROR or a Priming Failure alarm). The OptiFlo guide breaks the same symptom down further: no water in the strainer pot, a lid that is not tight, a damaged lid O-ring, the pool level below the skimmer, a clogged basket, a closed valve, or an air leak in the suction line.
Likely causes
- No water in the strainer pot
- Strainer pot lid not tight, or the lid O-ring/gasket damaged or unseated
- Pool water level below the skimmer opening, drawing air
- Strainer basket or skimmer basket clogged with debris
- A valve closed in the piping system
- Air leak in the suction line, at suction piping joints or valve glands
- Clogged impeller (shows as priming failure with reduced flow)
How to fix it — step by step
- Turn off electrical power to the pump at the breaker, and release all pressure from the filter, pump and piping system before opening anything (Pentair's required first step; on the filter, use its air relief valve).
- Check the pool water level: Pentair specifies about halfway up the skimmer opening. Below the skimmer mouth the pump draws air and loses prime, so correct the level first.
- Turn the pump lid clamp and lid counter-clockwise until they stop and lift them off. Fill the pump strainer pot and volute with water, up to the suction inlet. If your system is flooded suction (water source higher than the pump), it primes itself when the suction and discharge valves are opened instead.
- Empty the strainer basket while the lid is off, then clean and inspect the lid O-ring and make sure it is seated in its groove. On IntelliFlo lids, do not lubricate the O-ring: Pentair fits an internally lubricated O-ring, and only a non-original replacement may need a silicone-based lubricant. A defective strainer gasket is replaced, not reseated.
- Reinstall the clamp and lid and tighten by hand only, no wrenches. Open every suction and discharge valve, open the air release valve on the filter, and stand clear of the filter.
- Restore power and start the pump (on an IntelliFlo, select a speed and press Start; the drive runs its priming cycle). When water, not air, comes out of the air release valve, close it. The system is primed when water circulates with no air bubbles showing in the strainer pot or at the pool returns.
- If it will not prime, work Pentair's chart in order: check the suction piping and the valve glands on any suction gate valves for the air leak, confirm the lid is secured with its gasket in place, and confirm the suction lines, pump, strainer and volute are all full of water. On a two-speed pump, prime on high speed, not low.
- If prime still fails and flow was weak before, check the impeller for a clog: power off, remove the bolts holding the housing (strainer pot/volute) to the seal plate, slide the motor and seal plate away from the volute, and clean debris out of the impeller. Reassemble with the diffuser and O-rings back in place and the housing bolts tightened securely, then repeat the prime from the fill step.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the lid O-ring.
Also tied to this fault: strainer basket - Shop at Amazon
Parts that commonly fix it
- lid O-ringShop at Amazon
- strainer basket$15–$45Shop at Amazon
- Tools for this job, if you need them$10–$20
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.